Anytime any maintenance or repairs are done (including clearing jams), FIRST:

1. 

Disconnect the Nailer from its air supply.

2. 

Empty the Magazine Assembly (70) completely.

3. 

Attempt to fire the Nailer into a piece of scrap wood to ensure that it is  

 

 

disconected and is incapable of firing any Brads.

CLEARING JAMS

 

 

Use eye and ear protection when clearing jams.  Always wear ANSI    

 

approved impact safety goggles and appropriate hearing protection.

1. 

Occasionally, a Brad may become jammed in the firing mechanism of the    

 

Nailer, making the tool inoperable.

2. 

To remove a jammed Brad, disconnect the Nailer from its air supply. 

3. 

Slide the Pusher (63) back until it locks in place.  Then, lean the Nailer back.

4. 

Remove all Brads from the Magazine Assembly (70).

5. 

While holding the Pusher (63) in place, press the Release (74) and slide the  

 

Pusher forward all the way.

6. 

Attempt to fire the Nailer into a piece of scrap wood to ensure it is disconnected    

and is incapable of firing any Brads.

7. 

With the Driver Guide Cover (52A) facing away from you, push the Locker Spring 

(92) and remove Driver Guide Cover.

8. 

Remove the jammed Brad.

9. 

Close the Driver Guide Cover (52A), making sure it locks in place. 

10.  Reload the Nailer with Brads.  Then, reconnect the air supply hose to the tool.

11.  Press the Safety (50A) against a piece of scrap wood, and test fire the Nailer  

several times while checking for proper operation.  If the Nailer is properly firing, 

you may continue using the tool.  If the tool fails to perform properly, immediately 

discontinue use and have the tool repaired by a qualified service technician.

12.  When finished working, disconnect the air supply.  Remove the Brads. Then,  

 

store the Nailer in a clean, dry, safe location out of reach of children.

Summary of Contents for 94481

Page 1: ...Mission Oaks Blvd Camarillo CA 93011 Visit our website at http www harborfreight com Read this material before using this product Failure to do so can result in serious injury SAVE THIS MANUAL Copyrig...

Page 2: ...the presence of flammable gases or liquids 3 Keep children away Children must never be allowed in the work area Do not let them handle machines tools extension cords or air hoses 4 Store idle equipmen...

Page 3: ...ortion of the tool s operating controls are inoperable disconnected altered or not working properly 10 Disconnect air hose and release any built up air pressure Never service the Nailer clear jams or...

Page 4: ...an extension cord may cause your circuit breaker to trip or your panel fuse to break If this happens either use the compressor without an extension cord or find a larger amperage circuit to use 19 Ma...

Page 5: ...peration the Nailer may kick back causing injury 28 Transport Nailer safely Always disconnect air supply when moving the tool in the workplace Carry the tool by the handle to avoid contact with the tr...

Page 6: ...ty the Magazine Assembly 70 of Brads 3 The Nailer should not fire if the Safety 50A is not depressed against the workpiece 4 Make sure the Trigger 36 and Safety 50A move freely without sticking OPERAT...

Page 7: ...y a qualified service technician 8 Depress the Safety 50A against the workpiece and squeeze the Trigger 36 The tool must cycle fire only once Release the Trigger and squeeze it again The tool must not...

Page 8: ...on the workpiece The Nailer should not fire if the Safety is not depressed Once depressed gently and briefly squeeze the Trigger 36 once one Brad will be fired 4 Do not press the Safety 50A against th...

Page 9: ...ne Assembly 70 5 While holding the Pusher 63 in place press the Release 74 and slide the Pusher forward all the way 6 Attempt to fire the Nailer into a piece of scrap wood to ensure it is disconnected...

Page 10: ...Check for fastener jams Clear the jam if necessary 5 Have a qualified service technician check out the tool Sluggish operation 1 Make sure the compressor is set between 70 to 120 PSI 2 Check all air c...

Page 11: ...OOL ONLY NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER...

Page 12: ...SKU 94481 For technical questions please call 1 800 444 3353 PAGE 12 ASSEMBLY DIAGRAM...

Page 13: ...tal or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHAN...

Reviews: