5. 

Connect the air supply to the tool at the Quick Connector (83).  Set the regulator   

at the recommended 70 to 120 operating PSI.  Do not exceed the maximum    

120 PSI.

6. 

Test the tool by depressing the Safety (50A) against the workpiece without  

 

pulling the Trigger (36).  The tool must not cycle (fire).  If it cycles (fires), stop    

immediately and have it repaired by a qualified service technician.

7. 

Hold the tool away or off the workpiece.  The Safety (50A) of the tool should  

 

return to its original position.  Squeeze the Trigger (36).  The tool should not    

cycle (fire).  If the tool cycles (fires), stop immediately and have it repaired by a    

qualified service technician.

8. 

Depress the Safety (50A) against the workpiece and squeeze the Trigger (36).    

The tool must cycle (fire) only once.  Release the Trigger and squeeze it  

 

again.  The tool must not cycle (fire).  With the Trigger held, carefully lift   

the Nailer and press it against the workpiece again.  The tool must not cycle    

(fire).  If it fails to perform in the manner explained in bold, have it repaired by a    

qualified service technician.

LOADING BRADS

 

          WARNING: Always wear ANSI approved impact safety goggles when    

 

reloading or performing any other maintenance on this tool.  Other    

 

people in the work area must also wear ANSI approved impact safety  

 

 goggles.

1. 

Slide the Pusher (63) back until it locks in place.

2. 

Place a full clip of the desired size Brads (3/4” to 2”) in the Magazine Assembly    

(70).  Up to 100 Brads may be loaded in the Magazine.

Pusher (63)

Magazine 

Assembly (70)

REV 08g

Summary of Contents for 94481

Page 1: ...Mission Oaks Blvd Camarillo CA 93011 Visit our website at http www harborfreight com Read this material before using this product Failure to do so can result in serious injury SAVE THIS MANUAL Copyrig...

Page 2: ...the presence of flammable gases or liquids 3 Keep children away Children must never be allowed in the work area Do not let them handle machines tools extension cords or air hoses 4 Store idle equipmen...

Page 3: ...ortion of the tool s operating controls are inoperable disconnected altered or not working properly 10 Disconnect air hose and release any built up air pressure Never service the Nailer clear jams or...

Page 4: ...an extension cord may cause your circuit breaker to trip or your panel fuse to break If this happens either use the compressor without an extension cord or find a larger amperage circuit to use 19 Ma...

Page 5: ...peration the Nailer may kick back causing injury 28 Transport Nailer safely Always disconnect air supply when moving the tool in the workplace Carry the tool by the handle to avoid contact with the tr...

Page 6: ...ty the Magazine Assembly 70 of Brads 3 The Nailer should not fire if the Safety 50A is not depressed against the workpiece 4 Make sure the Trigger 36 and Safety 50A move freely without sticking OPERAT...

Page 7: ...y a qualified service technician 8 Depress the Safety 50A against the workpiece and squeeze the Trigger 36 The tool must cycle fire only once Release the Trigger and squeeze it again The tool must not...

Page 8: ...on the workpiece The Nailer should not fire if the Safety is not depressed Once depressed gently and briefly squeeze the Trigger 36 once one Brad will be fired 4 Do not press the Safety 50A against th...

Page 9: ...ne Assembly 70 5 While holding the Pusher 63 in place press the Release 74 and slide the Pusher forward all the way 6 Attempt to fire the Nailer into a piece of scrap wood to ensure it is disconnected...

Page 10: ...Check for fastener jams Clear the jam if necessary 5 Have a qualified service technician check out the tool Sluggish operation 1 Make sure the compressor is set between 70 to 120 PSI 2 Check all air c...

Page 11: ...OOL ONLY NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER...

Page 12: ...SKU 94481 For technical questions please call 1 800 444 3353 PAGE 12 ASSEMBLY DIAGRAM...

Page 13: ...tal or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHAN...

Reviews: