background image

Page 7

SKU 98676

For technical questions, please call 1-800-444-3353.

grOuNDINg

 

TO prEVENT 

ELEcTrIc SHOcK 

AND DEATH FrOM 

INcOrrEcT grOuNDINg 

WIrE cONNEcTION: 

Check with a qualified 

electrician if you are in doubt 

as to whether the outlet is 

properly grounded.  Do not 

modify the power cord plug 

provided with the tool.  Never 

remove the grounding prong 

from the plug.  Do not use the 

tool if the power cord or plug 

is damaged.  If damaged, have 

it repaired by a service facility 

before use.  If the plug will not 

fit the outlet, have a proper 

outlet installed by a qualified 

electrician.

grounded Tools: Tools with Three 

prong plugs

3-prong plug and Outlet

1.  Tools marked with “Grounding Re-

quired” have a three wire cord and 

three prong grounding plug.  The 

plug must be connected to a properly 

grounded outlet.  If the tool should 

electrically malfunction or break 

down, grounding provides a low 

resistance path to carry electricity 

away from the user, reducing the risk 

of electric shock.  

(See 3-prong plug 

and Outlet.)

The grounding prong in the plug is 

2. 

connected through the green wire in-

side the cord to the grounding system 

in the tool.  The green wire in the cord 

must be the only wire connected to 

the tool’s grounding system and must 

never be attached to an electrically 

“live” terminal.  

(See 3-prong plug 

and Outlet.)

The tool must be plugged into an 

3. 

appropriate outlet, properly installed 

and grounded in accordance with all 

codes and ordinances.  The plug and 

outlet should look like those in the 

preceding illustration.  

(See 3-prong 

plug and Outlet.)

EXTENSION cOrDS

Grounded

1. 

 tools require a three wire 

extension cord.  

Double Insulated

 

tools can use either a two or three 

wire extension cord.
As the distance from the supply outlet 

2. 

increases, you must use a heavier 

gauge extension cord.  Using exten-

sion cords with inadequately sized 

wire causes a serious drop in voltage, 

resulting in loss of power and pos-

sible tool damage. 

(See Table A.)

  The smaller the 

gauge number of the wire, the greater 

the capacity of the cord.  For ex-

ample, a 14 gauge cord can carry a 

higher current than a 16 gauge cord.  

(See Table A.)

When using more than one exten-

3. 

sion cord to make up the total length, 

make sure each cord contains at 

This product

uses a

3-prong plug.

Summary of Contents for 98676

Page 1: ...t in serious injury Save this manual Copyright 2008 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without...

Page 2: ...SION CORDS 7 SYMBOLOGY 8 SPECIFICATIONS 8 UNPACKING 9 ASSEMBLY INSTRUCTIONS 9 WORK AREA SET UP 11 DEFINITION OF TERMS 11 ADJUSTMENTS 13 OPERATING INSTRUCTIONS 13 MAINTENANCE AND SERVICING 15 TROUBLESH...

Page 3: ...t symbol indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury CAUTION without the safety ale...

Page 4: ...id safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries Remove any adjusting key or c wrench before turning the power tool on A wrench or a key lef...

Page 5: ...ing contact Harbor Freight Tools for a replacement Do not run the Lathe without its cov 2 ers and guards in place Tighten all locks before operating 3 Do not mount a split workpiece 4 Use the lowest s...

Page 6: ...ctrical shock Any power cord must be properly grounded Ground Fault Circuit Inter rupter GFCI should also be imple mented it prevents sustained elec trical shock Some dust created by power sand 22 ing...

Page 7: ...prong in the plug is 2 connected through the green wire in side the cord to the grounding system in the tool The green wire in the cord must be the only wire connected to the tool s grounding system a...

Page 8: ...100 150 0 2 0 18 18 18 18 16 2 1 3 4 18 18 18 16 14 3 5 5 0 18 18 16 14 12 5 1 7 0 18 16 14 12 12 7 1 12 0 18 14 12 10 12 1 16 0 14 12 10 16 1 20 0 12 10 TABLE A Based on limiting the line voltage dr...

Page 9: ...Note For additional information regarding the parts listed in the following pages refer to the Assembly Diagram near the end of this manual NOTE This product is very heavy 1 282 2 lb The following as...

Page 10: ...tock hole To remove either the Headstock Spur or Tailstock Spur insert the Push Out Rod into the hole at the opposite end of the Headstock or Tailstock See Figures D and E FIGURE D FACEPLATE 2 WRENCH...

Page 11: ...th of the lathe Between Centers A dimension representing the maximum length of a workpiece that can be turned between centers Also a method of holding a workpiece by mounting it between the centers of...

Page 12: ...14 5 8 swing meaning that the maximum size workpiece that can ro tate without hitting the bed is 14 5 8 in diameter Tailstock Assembly that slides along the ways and can be locked in place Used to ho...

Page 13: ...ch and store it in a safe location See Figure I FIGURE I POWER SWITCH 71 3 The Motor 13 of the Lathe must be running before you can use the Speed Control Lever 48 4 The Speed Control Lever 48 4 can 4...

Page 14: ...dle Wheel 67 end Use the Push Out Rod 22 to remove the center cup or to drill holes through the center of a workpiece See Figure L FIGURE L HANDLE ASSY 64 TAILSTOCK LOCK HANDLE 59 HANDLE WHEEL 67 TAI...

Page 15: ...ower Switch 71 of the Lathe to its OFF position and unplug the tool from its electrical outlet before performing any inspection maintenance or cleaning procedures To prevent serious injury from tool f...

Page 16: ...sure lathe is plugged into 2 a working 120 volt grounded electrical outlet Replace fuse or reset circuit 3 breaker Lathe will not turn off Damaged or faulty power switch 1 and or internal wiring Unpl...

Page 17: ...W 4 41 HEX WRENCH 4 42 BOLT A 1 43 CLAMP A 1 44 HEX NUT 3 45 ANGULAR SETTING ASSEMBLY 1 46 SCREW 2 NO DESCRIPTION Q TY 47 WRENCH 1 48 GEAR ASSEMBLY 1 48 1 SPRING BASE 1 48 2 KNOB 1 48 3 BOLT 1 48 4 SP...

Page 18: ...Page 18 SKU 98676 For technical questions please call 1 800 444 3353 ASSEMBLY DIAGRAM...

Page 19: ...maintenance We shall in no event be liable for death injuries to persons or property or for incidental contingent special or consequential damages arising from the use of our product Some states do no...

Reviews: