i-KI Commissioning with Nadi Controller 

This document must be read in association with the i-KI installation manual provided with the 
unit. The purpose of this document is to assist with the commissioning of the heat pump. It is 
essential the manual is read and followed to ensure the installation is per manufacturers 
criteria. 

 

There are various systems/set ups the Heat Pump can be installed to. This document will 
covers the most common options: 

     Pre-Commissioning  

 

 

 

 

 

Page 1 

B. Underfloor with Aube Thermostat   

 

 

 

Page 6 

C. Underfloor with Aube Thermostat and DHW  

 

 

Page 8 

D. Underfloor with Buffer Tank, Aube Thermostat and DHW 

Page 12 

E. Underfloor with Nadi Controller 

 

 

 

 

Page 14 

     Final Notes 

– Complete commissioning, checking  

 

 

Temperatures, Troubleshooting 

 

 

Page 16 

 

1. 

Prior to Commissioning 

A)  Ensure the heat pump is installed in accordance with the installation manual.  
B)  Ensure the power is isolated to the unit 
C) Remove the side cover of the unit to expose the water pump, compressor and electrical 

enclosure.  

D) Check that the water pump on the unit is free to turn and not seized. In addition please 

check any internal pumps.  

E)  Fill the system with water and ensure all air is removed.  

 

2.  Fill the system with water 

The system can now be filled with 
water to around 1 bar pressure.  

The iKi heat pumps have a pump 
run switch on the small PCB 
under the front cover of the heat 
pump on the smaller heat pumps, 
and under a panel on the side of 
the larger models.  This allows 
the circulation pump to be run 
manually to help vent the system. 

 

 

 

 

Leave the unit on standby for 2 hours once filled. 

Before the heat pump runs for the first time it is necessary to let it stand for 2 hours 
with the power on.  This is to allow the heating band around the compressor to heat 
the compressor to drive off any liquid refrigerant in the compressor.  This is 

Summary of Contents for i-KI

Page 1: ...nstalled in accordance with the installation manual B Ensure the power is isolated to the unit C Remove the side cover of the unit to expose the water pump compressor and electrical enclosure D Check...

Page 2: ...tting the clock can be completed 3 What happens when you turn on the main isolator The Nadi controller room unit will go through an initialisation phase that can last a few minutes and will show Cn fo...

Page 3: ...he menu within the Nadi Controller press and hold the and for 3 secs if the sun symbol on the top left hand corner appears press the mode button to turn it off we do wish for the heat pump to run yet...

Page 4: ...red parameter on the screen press the knob to confirm Turn the knob to adjust the setting Press the knob to confirm the adjusted setting 7 Menu Settings The table below shows the various menus for acc...

Page 5: ...e correct pockets Heating is controlled with the Aube Thermostat It must be connected to SA1 via a relay The schematic on the next page shows an Omron Relay and the relevant connections Should an alte...

Page 6: ...sation Determine if the heating will operate from fixed return set point or outside weather compensation Return Set Point Menu 1 parameter 0152 weather compensation ensure this is set at 0 0 disabled...

Page 7: ...lash This will keep flashing as long as the sniffing is in process This is defaulted at 3 minutes In addition once the water has reached temperature the heat pump will also sniff for a period of 10 mi...

Page 8: ...s necessary It is recommended that a flow switch is installed Should you not install a flow switch then it is necessary to install a bridge between terminals 39 and 40 i KI Internal Module Final Wirin...

Page 9: ...CHNZ if an alternative tank is being used It is also advised that a temperature set point of 50 o C There are 2 set points for DHW Comfort and Economy The comfort set point is the required set point t...

Page 10: ...at pump is trying to provide heating Before the heat pump runs the compressor to produce heat it first runs it s circulating pump to test the temperature of the water passing through the heat pump Thi...

Page 11: ...ed with the Aube Thermostat It must be connected to SA3 via a relay The schematic below shows an Omron Relay and the relevant connections Should an alternative relay be used please ensure you check th...

Page 12: ...arameter 0153 adjust the set point as required typically 45 for underfloor heating Weather Compensation Menu 1 parameter 0152 change to 1 Menu 1 parameter 0159 set the compensation curve from the grap...

Page 13: ...or a while and then resume or it may continue to run Either way while the compressor is running the three way valve will swing over to the open position and start to heat the cylinder Check for the co...

Page 14: ...placed inside the wiring module Check BT1 and BT2 probes are in the correct pockets Heating is controlled using the Nadi Controller SA1 is supplied with a loop This must be left in placed to control t...

Page 15: ...ump is sniffing the pump symbol at the bottom of the screen will flash This will keep flashing as long as the sniffing is in process This is defaulted at 3 minutes In addition once the water has reach...

Page 16: ...shows what the temperature sensors are reading 0900 return temperature 0901 flow temperature 0902 DHW sensor temperature 0904 Storage tank buffer tank temperature The buffer tank sensor is not normal...

Reviews: