white vinegar blend to remove any accumulated impurities inside boiler and
pipe, as following:
y
Wash the pipe in the tank and its filter head.
y
Pour out any liquid inside, and replace with the cleaning liquid (80% distilled
water and 20% white vinegar), turn on power, keep it operating till the cleaning
liquid runs out.
y
If the haze turns less, and the pump makes noise, switch off the unit immediately
and check fluid level, fuse, controller interface and power plug. If all of these are
normal, please connect power again. If problems still continue, please contact
the supplier.
y
When you shut down the machine, it is recommended that you remove any
remaining fluid inside. Especially when the machine will not be used for a long
time. It is recommended that you open the tank, remove the fluid hose and
place it next to the tank in open air.
y
After use, let the haze machine cool down before transporting it by the handle.
Small bits of haze may still be emitted just after the machine is turned off. Let
the machine cool down for at least 20 minutes and only transport it when the
housing of the machine reaches a temperature that is comfortable enough to
handle. Transporting the machine while it is still hot may cause injuries and per-
manent damage to the internal electronics and heating elements.