background image

42007193-003 R1

Installation Guide

for EHE0200158 Frost Thermostat

Frost Thermostat Application

Fixing holes spaced 
to suit BS4662

Screws supplied

Use wall box fixing holes 
or alternatives shown

Screws supplied

3. Wiring options

2. Mount the backplate to wall

1. Remove the cover from the backplate

a. Wall box mounting

b. Surface mounting

CAUTION:

 Disconnect 

system power supply 
before removing cover.

a. Wall box wiring

b. Surface wiring

The Frost Thermostat can be installed to protect either the whole 
central heating system, or the boiler and localised pipework.

If the Frost Thermostat is installed to protect the central heating 
system it must be sited within the dwelling in a place where a 
rise and fall in ambient air temperature can be detected i.e. in a 
room with a radiator.  The wiring for this is shown in the wiring 
diagram overleaf.

The Frost Thermostat must be wired to override all other time 
and temperature control and preferably to switch on the 
heating circuit, rather than the hot water circuit.

When a Frost Thermostat is installed on a central heating 
system, the Connection Unit should only be switched off for 
servicing or maintenance.  If the system is to be switched off 
for any other reason e.g. holiday, then switching MUST only be 
carried out at the programmer or time clock.