6. MEASURING INSTRUCTION
6-1 ACA Measurement
:
With the clamp disconnected from any conductor, switch the
function selector to range.
Open the clamp by pressing the jaw-opening handle and insert the
Cable to be measured into the jaw.
Close the clamp and get the reading from the LCD panel.
Note:
Before this measurement, disconnect any test lead with the meter
for safety.
In some cases where reading is difficult, press the HOLD button and
read the result later.
CORRECT
INCORRECT