Electric pump 230 V
a
Mount the pump on the pump support with:
4 x hex screws M6 x 20
4 x spring washer A6
4 x washer A6.4
b
Remove the protective caps from the discharge hose
and the pump. Connect the connector with the seal to
the pump‘s suction side.
c
Remove the protective cap from the connection line.
Connect the filling hose with delivery nozzle to the
connection line / spacer.
b
c
Electric pump 230 V
with meter
a
Connect the connection line to the pump 30° down-
wards. Spacer not required.
b
Fit pump on the pump support using:
4 x hex screws M6 x 20
4 x spring washer A6
4 x washer A6.4
c
Remove the protective caps from the discharge hose
and the pump. Connect the connector with the seal to
the pump‘s suction side.
d
Fit the meter on the connection line.
e
Connect the filling hose with delivery nozzle to the
meter.
a
b
c
d
e
a
7