10
Before starting conversion always check that the ram is completely retracted and the pump
hose is disconnect from the head.
- FROM SINGLE TO DOUBLE ACTING -
– Remove upper plug vent from the head, insert
female coupler Q38-F and nipple 3/8” NPT,
using appropriate pipe thread sealant and tighten
to 30 Nm (22 lbf ft).
– Connect appropriate high pressure hoses from
a suitable power source (10,000 psi) and operate
as a double acting hydraulic tool.
UPPER
PLUG VENT
COUPLER
FEMALE
COUPLER Q38-F*
FEMALE
COUPLER
NIPPLE
3/8” NPT *
- FROM DOUBLE TO SINGLE ACTING -
– Remove female coupler and nipple from the head.
– Tip the head to pour oil from upper cylinder into a
suitable container.
– Insert supplied vent using appropriate pipe thread
sealant and tighten to 30 Nm (22 lbf ft).
Check that the oil is completely drained, before inserting
the plug vent.
– Connect appropriate high pressure hose from a suitable
power source and operate as a single acting hydraulic tool.
SINGLE
ACTING
DOUBLE
ACTING
LOWER PRESSURE PORT:
ram advancing
UPPER RETURN PORT:
ram returning
*
optional accessories:
Q38-F
code 6060126
NIPPLE
code 6525090
4. CONVERSION INSTRUCTIONS