14
8. CARE AND MAINTENANCE
The
Cembre
insulated cable cutting units are designed for on site use and thanks to its construc-
tion characteristics it is a technical and robust operating device.
To guarantee the reliability of the device for a long period, the following instructions must be
complied with:
– Regularly remove dirt (depending on how often it is used) from the cutting head, cylinder, blades
and seals using a brush dipped in a liquid detergent. Dry the area carefully.
– Carefully clean the quick couplings and their protection covers each time the unit is used.
– Clean the anchoring screws of the pedal; the pin and blade guide of the cutting head must be
lubricated with a few drops of oil, to avoid seizing if it is used continuously.
– Every 6 months check the oil level in the tank and if necessary top up.
Oil top up
– Position the pump on a gradient so that the air collects at the filler in put hole and the oil is able
to enter freely.
– Release the pedal to make the tank cap easier to access.
– Remove the cap and pour in the oil.
The oil must reach the bottom of the threading of the hole in
the tank.
– Close the oil tank with the cap.
The pump is ready for use again.
Reservoir cap
When topping up always
use the oil specified in
point 3.
Never top up with old or
used oil.
The oil must be clean.
O
IL
Ö
l
~ 250 mm
ENGLISH