7.4) ERRORS:
these appear during operation, combined with a beep and flashing LED Worklights,
to notify the operator of procedural or operational errors.
Message
Error description
Solution
ERROR
The pressure release button (5)
was pressed before the control
parameters were reached (Force/
Pressure).
Repeat the work cycle and wait for the
motor to stop automatically.
001
Abnormal power consumption
of the motor for more than 3
seconds.
The tool stops.
Wait for the display to turn off (60 sec.)
or remove and re-insert the battery,
then re-start the tool.
If the error occurs frequently, contact
Cembre.
002
Output voltage of the pressure
transmitter is out of the pre-set
range.
Repeat the work cycle; if the errors
reoccurs frequently, contact Cembre.
003
Failure to reach the set pressure
within 30 seconds of continuous
operation of the machine.
Repeat the work cycle; if the errors
reoccurs frequently, contact Cembre.
004
Overcharging of the battery with
protection tripping.
The tool stops.
Wait for the display to turn off (60 sec.)
or remove and re-insert the battery,
then re-start the tool.
If the error occurs frequently, contact
Cembre.
Errors are displayed for about 30 seconds before being reset, but will display repeatedly in
the event of permanent anomalies.
8. CONNECTION TO COMPUTER
The memory card integrated in the tool records operating data from 200.000 cycles for transfer via
the USB cable supplied.
To view and manage this data, go to
www.
cembre
.com
and register in the dedicated area, then
download the free
Cembre
software
CEM_SWBT01
.
Keeping the Firmware of the tool updated, via free of charge download from here, will optimise
the tool's performance.
9. RETURN TO
Cembre
FOR OVERHAUL
In the case of a breakdown contact our Area Agent who will advise you on the problem and give
you the necessary instructions on how to dispatch the tool to our nearest service Centre; if possible,
attach a copy of the Test Certificate supplied by
Cembre
together with the tool or fill in and attach
the form available in the “ASSISTANCE” section of the
Cembre
website.
ENGLISH