1.Safety

International Safety Symbols

Safety Notes

WARNINGS

CAUTIONS

This symbol, adjacent to another symbol or terminal, indicates the user must
refer to the manual for further information.

This symbol, adjacent to a terminal, indicates that, under normal use, hazardous
voltages may be present

Double insulation

•Do not exceed the maximum allowable input range of any function
•Do not apply voltage to meter when resistance function is selected.
•Set the function switch OFF when the meter is not in use.

•Set function switch to the appropriate position before measuring.
•When measuring volts do not switch to current/resistance modes.
•When changing ranges using the selector switch always disconnect the test leads

from the circuit under test.

•Do not exceed the maximum rated input limits.

Improper use of this meter can cause damage, shock, injury or death. Read and

understand this user manual before operating the meter.

Always remove the test leads before replacing the battery.
Inspect the condition of the test leads and the meter itself for any damage before

operating the meter. Repair or replace any damage before use.

Use great care when making measurements if the voltages are greater than 25VAC

rms or 35VDC. These voltages are considered a shock hazard.

Remove the battery if the meter is to be stored for long periods.
Always discharge capacitors and remove power from the device under test before

performing Diode, Resistance or Continuity tests.

•Voltage checks on electrical outlets can be difficult and misleading because of

the uncertainty of connection to the recessed electrical contacts. Other means should

AC Clamp Meter User Manual

Summary of Contents for FC-35

Page 1: ...Please read this manual before switching the unit on Important safety information inside User Manual AC Clamp Meter User Manual AC Clamp Meter...

Page 2: ...AC Clamp Meter User Manual...

Page 3: ...ation 4 1 AC Current Measurements 4 2 AC DC Voltage Measurements 4 3 Resistance and Continuity Measurements 4 4 Diode Measurements 4 5 MAX Hold 4 6 Backlight 4 7 Battery Replacement Description 3 Spec...

Page 4: ...ircuit under test Do not exceed the maximum rated input limits Improper use of this meter can cause damage shock injury or death Read and understand this user manual before operating the meter Always...

Page 5: ...display MAX Hold Backlight button Mode select button COM input jack V 2 Description Meter Description 1 2 3 4 5 6 7 8 jack Battery Cover Non contact AC voltage NCV indicator light 9 10 AC Clamp Meter...

Page 6: ...ure list AC DC 1 8 8 8 AC DC AC Clamp Meter User Manual 3 Specifications Function AC Current DC Voltage AC Voltage Resistance Range Resolution 200 0 AAC 200 0 mVDC 2 000 VDC 20 00 VDC 200 0 VDC 600 VD...

Page 7: ...e 10 000m Category II 600V Category III 300V Two 1 5V AAA Batteries approx 15 minutes 164x65x32mm 175g For indoor use and in accordance with Overvoltage Category II Pollution Degree 2 Category II incl...

Page 8: ...urements Set the Function switch to the range If the range of the measured is not known select the higher range first then move to the lower range if necessary 1 Press the trigger to open jaw Fully en...

Page 9: ...ouch the test probe tips across the circuit or component under test It is best to disconnect one side of the device under test so the rest of the circuit will not interfere with the resistance reading...

Page 10: ...ding encountered since the MAX hold button was pressed Press the MAX hold button again to return to normal operation The backlight function illuminates the display and is used when the ambient light t...

Page 11: ...AC Clamp Meter User Manual...

Page 12: ...Rev 140211 AC Clamp Meter User Manual...

Reviews: