background image

10

Non-Contact Forehead InfraRed Thermometer

6.Graphic Symbol Description

The device is in accordance with Medical
Device Directive 93/42/EEC 
The device is in accordance with FCC Part
15 Subpart B
3V DC power supply
In order to protect the environment, please
recycle the battery according to the local
regulations.

Please read the instructions for use

Attention, consult accompanying documents
Type B equipment
The name and the address of the
manufacturer

Summary of Contents for DT-8807H

Page 1: ...Operating Instruction for Non Contact Forehead InfraRed Thermometer Please read this manual before switching the unit on Important safety information inside...

Page 2: ......

Page 3: ...rature 8 2 Measure Surface Temperature 9 Function Setting 9 1 Body Surface Setting 9 2 Temperature Unit Setting 9 3 Buzzer ON OFF 9 4 Longevity Use 10 Maintenance and Cleaning 11 This Appliance Confor...

Page 4: ...cially designed to take the body temperature of a person regardless of room temperature Depending on various skin types and thickness there may be temperature difference When the room temperature is s...

Page 5: ...und with cordless or cell phones Keep the device away from water and heat including direct sunlight Do not drop or knock the device and do not use if damaged It may affect the accuracy of measurements...

Page 6: ...the surface temperature Use of this thermometer is not intended as a substitute fo consultation with your physician Should a problem occur with your device please contact your retailer do not attempt...

Page 7: ...ter 4 Features Precise non contact measurements Selectable Body and Surface temperature User selectable C or F Memorization of the last 10 measurements Automatic Data Hold Auto power off Display Resol...

Page 8: ...8 Non Contact Forehead InfraRed Thermometer 5 Description 5 1 Meter Description 1 Detector 2 Probe Cover 3 LCD Display 4 Memory Set Button 5 Measure Button 6 Battery Cover 6 1 3 4 5 2...

Page 9: ...t Forehead InfraRed Thermometer 5 2 Display Description 1 Buzzer ON OFF Symbol 2 Body Symbol 3 Surface Symbol 4 Low Power Indication 5 Measure Data 6 C F Symbol 7 Memory Symbol 8 The Last Reading 1 2...

Page 10: ...tive 93 42 EEC The device is in accordance with FCC Part 15 Subpart B 3V DC power supply In order to protect the environment please recycle the battery according to the local regulations Please read t...

Page 11: ...ge Indication Spectral Response Power Off Operating Temp Storage Temp Humidity Rate Power Battery Life 32 0 to 42 C 89 6 to 107 6 F 0 to 60 C 32 to 140 F 0 3 C 1 4cm 1s LCD will show Hi Lo 8 to 14 m A...

Page 12: ...Body Temperature mode and LCD display the 3 Hold the meter by its handle and point it toward the forehead to be measured 4 Press the Measure Button to turn the meter on and take a temperature reading...

Page 13: ...he 3 Hold the meter by its handle and point it toward the forehead to be measured 4 Press the Measure Button to turn the meter on and take a temperature reading 5 If the battery power is enough the LC...

Page 14: ...ing Press Button for 2 seconds F2 will Memory Set appear in the display Release the button press Measure Button to change temperature unit 9 3 Buzzer ON OFF Press Button for 2 seconds F3 will Memory S...

Page 15: ...ted carefully Clean the device with a cotton bud lightly moistened with 70 isopropyl alcohol do not clean the device with corrosive detergent Keep the device away from water or other liquid Store the...

Page 16: ...dical electrical equipment Part 1 General requirements for safety IEC 60601 1 EN60601 1 11 Medical electrical equipment Part 1 11 General requirements for basic safety and essential performance Collat...

Page 17: ...ry cover and change battery Remove battery from the device if it is not going to be used for a long time to extend battery life and to avoid damage to the device for due to leakage Please note battery...

Page 18: ...en display the message Hi when using the non contact Body infrared thermometer the message HI can show on the screen The analysis is above the measurement range selected either superior to 42 C 107 6...

Page 19: ...Emissions Compliance Group 2 Class B Not applicable Not applicable Guidance and Manufacturer s Declaration Electromagnetic Emissions The DT 8807H is intended for use in the electromagnetic environmen...

Page 20: ...d for use in the electromagnetic environment specified below The customer or the user of the DT 8807H should assure that it is used in such an environment Immunity Test Electrostatic discharge ESD lEC...

Page 21: ...ironment Guidance Portable and mobile RF communications equipment should be used no closer to any part of the DT 8807H paration distance calculated from the equation applicable to the frequency of the...

Page 22: ...roadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured fiel...

Page 23: ...of the communications equipment Rated Maximum Output Power of Transmitter W 0 01 0 1 1 10 100 For transmitters rated at a maximum output power not listed above the recommended separation distance d in...

Page 24: ...sence of a flammable anaesthetic mixture with air or with oxygen or nitrous oxide Continous opration Type of protection against electric shock Degree of protection against electric shock Degree of pro...

Page 25: ...ve Directive 2020 96 EC and is effective only with in European Union The batteries must not be exposed to temperature above 65 C When your device is not used for a long time remove the battery out of...

Page 26: ......

Page 27: ......

Page 28: ...Industry Co Ltd 19th Building 5th Region Baiwangxin Industry Park Songbai Road Baimang Xili Nanshan Shenzhen China P C 518108 Tel 86 755 27353188 www cem instruments com Lotus NL B V Koningin Juliana...

Reviews: