Remark:
(1) The defaulted temperature of period3 and period4 is the same as
period2. Please change it according to the request.
(2) When setting temperature is 00, this period is power off.
Period
Week
Weekend
Period Icon Defaulted Time Defaulted Temp.
1
2
3
4
5
6
1
2
6:00
8:00
11:30
12:30
17:30
22:00
8:00
23:00
20
℃
15
℃
15
℃
15
℃
22
℃
22
℃
15
℃
15
℃
Press
M
to switch operation between manual mode and programmable
mode.
Display Code Function
Setting And Options Factory Defult
SVH
High limit temp.
for internal sensor
5-99
℃
35
℃
SVL
Low limit temp.
for internal sensor
5-99
℃
5
℃
ADJ
Temp.calibration
Check and calibrate the
actual room temp.
0.5
℃
accuracy
calibrate
FRE
Frost-protection
00
:
Close
00
PON
Power memory
00
:
Off
01
:
On
00
FAC
WIFI setting
10 or 32: Wifi mode open
00:
Positive output
7. Advanced Setting
In the state of power-off, long press and hold then press into
advanced setting mode. Then press
M
to set relative item.
For Opt:
When the thermostat connect with gas boiler, the terminal short circuit
is extinguished, the open circuit is ignition. Then Turn to the reverse output ‘01'.
IX. Phone Port Operation Instruction
1. Install APP on phone
For iOS system: Login in App Store, search “
Beok Home
”, you can
download it on your iphone.
For Android System: Login in Google Play, search “
Beok Home
”, you can
download it on your phone.
Or scan below code to download:
Or scan below code to download:
2. Connection Thermostat with Phone
Thermostat Setting
At this time, wifi symbol will be twinkling quickly and frequently. It means, you can
connect thermostat with phone now.
When wifi symbol stop twinkling, it means thermostat is successfully connected with
phone.
Twinkling Quickly and Frequently:
Connection can start
Twinkling slowly:
Off Line
Twinkling Stops:
Successful Connection
Connection with Phone
Open Beok Home APP on your phone, you can see APP welcome page
Powered off state
DFI
Precision
for room temp.
0.5-3
℃
1
℃
Opt
Linkage terminal
output direction
00:Set temp>Room temp,
relay close
01:Set temp<Room temp,
relay close
When the Opt is adjusted to 00, thermostat can also be used in the
water floor heating system, the water temperature is too low will prohibit the output
(relay output 3A/200W), this function only suits for wifi linkage function thermostat.
DFI:
DFI is hysteresis for room temp, factory set is 1,if 1 is too big for you,
it can be adjusted to 0.5.
08: just display
00: factory reset
08
01
:
Open
Explanation:
For example,If Room temp is 22
℃,
Hysteresis‘DFI’
=
1.
when
room
temp
rise
to 23
℃
,the relay will stop outputting;
when room temp down to 21
℃
, the relay will output again and start heating.
Time setting
Menu
20
In the power off state, long press the up button for 10 seconds
blue