TROUBLE SHOOTING
Problem
Cause
Solution
The Dehumidifier will not turn on
The power is not connected
Insert plug into mains power
supply and turn unit on
The Dehumidifier is not
extracting water
The water tank is full
Remove the water tank and
empty water
The water tank is not in its
correct position
Remove water tank and replace it
in its correct position
The air filter is clogged
Clean the air filter as per
instructions in user manual
The temperature or relative
humidity in the room is too low
It is normal for the Dehumidifier
not to operate in low humidity or
low temperatures
The Dehumidifier operates, but
reduces the relative humidity in
the room by small amounts
The room which the Dehumidifier
is operating in is too large
Recommend using a Dehumidifier
with a larger capacity
There are too many sources of
humidity
Recommend using a Dehumidifier
with a larger capacity
The room has too much
ventilation
Reduce the number of ventilation
sources (i.e. close windows,
doors, etc.
TECHNICAL SPECIFICATION
Model: CELDH145
Supply: 220-240VAC 50Hz
Wattage: 245W
Unit Capacity: 10L/day max (30
°
C/80%RH)
Tank Capacity: 2L
Refrigerant: R134a/130g
SUPPORT AND TECHNICAL ADVICE
Celsius
–
New Zealand
Monday
–
Friday 8am-5pm
Phone +64 (0)9 917 4000
Phone 0800 232 633
[email protected]
Celsius
–
Australia
Monday
–
Friday 8am-5pm
Phone +61 (0)3 9365 5100
Phone 1300 465 324
PROOF OF PURCHASE
To receive warranty retain receipt as proof of purchase.