Cellinx CamPilot MRH100-CP11MV User Manual Download Page 6

21 

Web Monitoring 

 

• 

D/O   

- Digital Out - This controls the device that is connected to CamPilot MRH100. 

 

• 

Bitrate

   

- Display the bitrate of current video stream. 

-  User  can  select  other  bitrate.  (If  CamPilot  MRH100  is  rebooted,  the  bitrate  on  the 

monitoring page is initialized to the designated value of “server setting page”.) 

- Changing the bitrate is not available on a guest account. 

 

• 

Enable Audio

   

- If the box is checked the CamPilot MRH100 sends the audio data with the video data. 

 

• 

PTZ Control 

- User can control a PTZ camera or receiver through RS485 

• Z (Zoom): zoom in (+) / zoom out (-) 

• Pan/Tilt : CamPilot MRH100 does not support Pan/Tilt function 

• F (Focus): focus in (+) / focus out (-) 

• PTZ control is not supported on a guest account 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

22 

Web Setting 

 

  SERVER SETTING 

- To apply the changed setting, reboot CamPilot MRH100.   

(Click 

Reboot 

on the menu) 

 

• 

Status 

- This is the initial page of Server Setting. 
- This shows network status, model information, network traffic status,   

connection list and system log. 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

23 

Web Setting 

 

• Network Status 

- MAC Address: Media Access Control Address of CamPilot MRH100 (Unchangeable) 
- IP Address: the assigned IP Address of CamPilot MRH100 
- Subnet Mask: Subnetwork of the IP address belongs to. 

(Use the value to fit the network environment) 

- Gateway: Gateway Address (Use the value to fit the network environment) 
- Default DNS: IP Address of Default DNS server 
 

• Connection List 

- User can check the number of connected clients and IP addresses. 
 

• Log   

- “Log” displays the logs of general events of CamPilot MRH100. 
 

• 

Basic > Network (Wired)

 

- User can set Network Information of CamPilot MRH100: IP Address, Subnet Mask, 

Gateway, Default DNS 

 

 Static IP 

 

24 

Web Setting 

 

- IP Address: Ask network administrator for an appropriate address 

- Subnet Mask / Gateway / Default DNS : Ask network administrator 

- After setting, click “OK” button 

- Click “Reboot” to apply the setting to CamPilot MRH100. 

 
 
 
 
 
 

 Dynamic IP 

 

- If DHCP server is on the local network and you intend to allocate IP address dynamically, 

use this method 

- Select 

Dynamic IP

 tab and click “OK” button, and reboot CamPilot MRH100. 

- If you want to select 

Dynamic IP

, set Dynamic DNS to access CamPilot MRH100. 

Click! 

< Reboot Message > 

Summary of Contents for CamPilot MRH100-CP11MV

Page 1: ...r and network interface Users can simply connect power source and network cable for operation Additional operation equipments or programs are not required Appearance and Accessories GND 1 D OUT D IN D...

Page 2: ...etwork Setting Setting an IP address of a CamPilot MRH100 TIP If a monitoring PC is on 192 168 1 xxx network area the connection is available without any change on CamPilot MRH100 The initial IP addre...

Page 3: ...k the port forwarding should be set for the connection from a public network area As the port forwarding is a setting item of a router a PC of the IP address on a public network can be connected to a...

Page 4: ...e CamPilot MRH100 on the address window of a web browser as below Refer to ENCP 2 1 program manual to set an IP address of the CamPilot MRH100 Connection and accounts Administrator account It is avail...

Page 5: ...current video stream AVI file creation route C Full Extends the image of current video stream to fit monitor size Resolution Displays a current resolution User can select other resolution If CamPilot...

Page 6: ...g 23 Web Setting Network Status MAC Address Media Access Control Address of CamPilot MRH100 Unchangeable IP Address the assigned IP Address of CamPilot MRH100 Subnet Mask Subnetwork of the IP address...

Page 7: ...IF fixed Bitrate Type CBR VBR Constant Bitrate 8M 7M 6M 5M 4M 2M 1 5M 1M 750K 500K 384K 256K 128K 64K 32K Variable Bitrate 1 6 The highest quality is 1 Frame Per Sec 1 30 NTSC 1 25 PAL Group Size 1 20...

Page 8: ...RH100to send the signal unit sec FTP Enable enables the CamPilot MRH100to send captured image to FTP server Assuming JPEG Capture enable on the video setting page Server IP address of FTP server Port...

Page 9: ...MRH100 keeps internally New Date Time user can assign the specific time voluntarily 35 Web Setting Time Server Time Server Enable enables the time of CamPilot MRH100 synchronize with time server peri...

Page 10: ...ct the installation place Mirror Flip makes the video mirror or flip ISP firmware update ver 11 10 00 00 This is used for technical support Please don t change anything on this item Expert PTZ This fu...

Page 11: ...the number of simultaneous access 1 20 43 Web Setting Expert DDNS DDNS is the function that matches an IP address and a host name If a CamPilot MRH100 has the dynamic IP address the host name by DDNS...

Page 12: ...nP Enable Check the box to use UPnP Universal Plug and Play of CamPilot MRH100 Friendly name User can change the friendly name of CamPilot MRH100 47 Web Setting Expert Motion Detect Input Setting Chec...

Page 13: ...e sending the CamPilot MRH100 out for repair check the items below If the problem persists after checking these items contact your service center If no image appears Is the LAN cable attached securely...

Reviews: