Celleration Ultramist Instructions For Use Manual Download Page 1

 GENERATOR
  1  

Generator

 

  2  

Power Switch (Back of Generator)

  3  

Generator Power Cord

  4  Peristaltic Pump
  5  Tubing Guides
  6  Adjustable Hook
  7  Indicator Light
  8  Treatment Wand Connector
  9  Treatment Wand Cradle
10  USB Port/Cover
 

TREATMENT WAND
11 

  

Treatment Wand

12  Display Screen
13  Keypad
14  Treatment Wand Cable with Connector
15  Tubing Channel
16  Treatment ON/OFF Button (Trigger)
17  Treatment Wand Tip

 

APPLICATOR
18  Applicator
19  Tubing-Cable Clip
20  Tubing Clamp
21  Infusion Tubing
22  Tubing Spike
23  Tubing Spike Protective Cover 

PLEASE READ INSTRUCTIONS BEFORE USE. 

UltraMIST

 

System

ULTRAMIST

 

SYSTEM

  

INSTRUCTIONS FOR USE

Other Materials Required

• 

0.9% Normal Saline 100cc - 1000cc bag

• 

Germicidal wipes for cleaning/disinfecting

• 

Absorbent pads

Caution:

 

Rx Only. This medical device is to be operated by a healthcare professional in accordance with the instructions for use.

Generator

Treatment Wand

Applicator

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

PL-61044_B

       

1

Summary of Contents for Ultramist

Page 1: ...Wand Tip APPLICATOR 18 Applicator 19 Tubing Cable Clip 20 Tubing Clamp 21 Infusion Tubing 22 Tubing Spike 23 Tubing Spike Protective Cover PLEASE READ INSTRUCTIONS BEFORE USE UltraMIST System ULTRAMIS...

Page 2: ...ed performance DESCRIPTION INDICATIONS FOR USE Description The UltraMISTTM System delivers low frequency ultrasound to the treatment site using a noncontact saline mist Indications for Use The MIST Th...

Page 3: ...the keypad to enter the size of each wound to be treated per the screen prompts 5 The total saline requirement for the combined treatment area is displayed approximately 100mL for every 25 cm2 Select...

Page 4: ...d close the pump door Leave enough tubing to allow the saline bag to hang freely with the majority of the tubing between the pump and treatment wand 13 Open the tubing clamp Saline will not flow until...

Page 5: ...or best results the treatment wand should be perpendicular to the wound and parallel to the floor during treatment Note It is important to maintain a 0 5 to 1 5 cm 0 2 0 6 inch distance from the leadi...

Page 6: ...l data is encrypted to prevent usage by unauthorized personnel WARNING DO NOT ATTACH ANY UNAPPROVED USB DRIVES CABLES OR EQUIPMENT TO THE DRIVE AS IT MAY INTERFERE WITH OPERATION OF THE DEVICE Accessi...

Page 7: ...PLICATOR Applicator has been previously used and should be replaced Replace applicator 201 REPOSITION APPLICATOR Applicator not positioned properly on treatment wand Adjust current applicator properly...

Page 8: ...software error Shut down system by turning off power and then restart If error continues call Celleration Customer Service OVERHEAT Treatment wand temperature has exceeded the allowed limit The system...

Page 9: ...r of applicator Ensure the applicator is positioned correctly with treatment wand tip located in center of applicator opening and fully seated on the applicator housing Tubing spike not fully mated wi...

Page 10: ...Celleration Customer Service PHONE 1 866 307 MIST 6478 ADDRESS 6321 Bury Drive Suite 15 Eden Prairie MN 55346 WEBSITE www Celleration com EMAIL customerservice celleration com TECHNICAL SERVICE ULTRA...

Page 11: ...re This End Up Keep Dry Recycle Authorized Representative in the European Community CE Mark Temperature Limit Consult Instructions for Use Manufacturer Date of Manufacture Lot Number Prescription Use...

Page 12: ...ation of nearby equipment It may be necessary to take mitigation measures such as re orienting or relocating the UltraMIST System or shielding the location Harmonic emissions IEC 61000 3 2 Class A Vol...

Page 13: ...stallation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inference to radio communications Ho...

Reviews: