Installation Instructions
NOTES:
•
Do not install any ducts onto the supply, return, intake and exhaust.
•
Mounting brackets, screws, gaskets and other seal materials are not included.
•
Because of potential safety hazards under a certain condition we strongly
recommend against the use of an extension cord. However, if you still select
to use an extension cord, it is absolutely necessary that it is a UL LISTED 3-
wire grounding type appliance extension cord having a 3-blade grounding
plug and a 3-slot receptacle that will plug into the appliance. The marked
rating of the extension cord shall be 115 V, 15 A or equivalent for
CT1500~2500ZD and 115 V, 20 A or equivalent for CT3500~8500ZD and not
greater than 15ft in length.
1. General Instructions
•
The cooling unit produces cooling supplied into the cellar, meanwhile it also
generates heat that must be exhausted outside the cellar. So the cold- air
supply with cellar-air return side and the hot-air exhaust with ambient-air
intake side must be separated and sealed. Through-wall installations can
separate these two sides.
•
Furthermore, the condenser of cooling unit must intake adequate fresh
ambient-air to work properly. The ambient-air intake and hot-air exhaust must
not be short-circulated. Both of them must remain unobstructed 36” clearance
all around. The area into which the hot air is exhausted must be well
ventilated. If it is not, heat generated by the unit will build up and the unit will
not operate properly.
•
Additionally, cold-air supply from the front grille must remain unobstructed 36”
clearance.
•
The ambient temperatures shall not be above and below what are specified
.
Summary of Contents for CT1500ZD
Page 5: ...4 Fig 1 2 CT3500 8500ZD FEATURE DESCRIPTIONS Fig 1 3 CT1500 2500ZD DIMENSIONS...
Page 9: ...8 Fig 2 2 THREAD INSERT Fig 2 3 REAR GASKET...
Page 10: ...9 Fig 2 4 TOP EXHAUST GASKET Fig 2 5 COOLING UNIT MOUNTING...
Page 11: ...10 Fig 2 6 SECURING BRACKET SCREW...
Page 12: ...11 Fig 2 7 CABINET GRILLE...