- 9 -
Factory Setup Menu
Setup Number
Setup Name
Settings
0120
Date (Year Upper)
Select first two digits of current calendar year
0130
Date (Year Lower)
Select last two digits of current calendar year
0140
Date (Month)
Select number for current calendar month
0150
Date (Day)
Select number for current calendar date
0160 Schedule
Options
0-nonprogrammable
0170
System Selection
6-cool only (default); 1-heat and cool
0180
Fan Control in Heating
0-by heating equipment
0220 Cycles
Per
Hour
2
0280
Continuous Backlight
0-not (default); 1-yes
0300
Cooling & Heating
Changeover
0-manual
0320
Temperature Display
0-fahrenheit (default); 1-celsius
0330
Daylight Savings
0-off (default); 1-on
0340
Remote Air Sensor
0-no (default); 3-indoor
0380
Indoor Dehumidification
0-no
0580
Min Compressor Off
5-five minutes off
0610
Min Cool Temp
50
°
F
0640
Clock Format
12-12 hour (default); 24-24 hour
0660
Extended Cool Fan On
0-0 seconds (default); 90-90 seconds
0670
Keypad Lockout
1-partially locked (default); 0-unlocked
0690
Cool Temp Control
2-standard
0700 Temperature
Offset
0-no
0710
Reset
0-No Reset (default); 1-Reset
NOTES:
•
The setup 0660 = 90 can be
used to increase the humidity in the wine cellar.
•
The setup 0660 = 90 can also be used for defrosting more efficiently if there is
excessive frost.
4) Press the DONE key to exit the Installer Setup screen.
Summary of Contents for CT12TSD
Page 19: ... 18 Fig 6 WM 65 85SFCD Evaporator Unit ...
Page 20: ... 19 Fig 7 WM 250 450SCU Condensing Unit Fig 8 WM 650 850SCU Condensing Unit ...
Page 21: ... 20 Fig 9 Liquid Filter Fig 10 Liquid Indicator Fig 11 Touch Screen Thermostat ...
Page 30: ... 29 Fig 19 CT12TSD Electrical Wiring Diagram Fig 20 CT34TSD Electrical Wiring Diagram ...
Page 32: ... 31 Fig 23 Low Ambient Temperature CT34TSD LA Electrical Wiring Diagram ...