background image

www.cellarcool.com | Page 25

CellarCool Product Terms and Conditions 

Including Product Limited Warranty And Product Installation Requirements

ATTENTION: PLEASE READ THESE TERMS OF USE CAREFULLY BEFORE INSTALLING YOUR CELLARCOOL COOLING 

SYSTEM. INSTALLING YOUR CELLARCOOL COOLING SYSTEM INDICATES THAT YOU ACCEPT AND AGREE TO EACH OF 

THE TERMS AND CONDITIONS SET FORTH HEREIN (“TERMS OF USE”). IF YOU DO NOT ACCEPT THESE TERMS OF USE, 

YOU RISK VOIDING YOUR WARRANTY AND ASSUMING ADDITIONAL REPAIR AND REPLACEMENT COSTS.

1. Purchase of a CellarCool Cooling System assumes that the Purchaser (“End User”) fully accepts and agrees 

to the Terms and Conditions set forth in this document. The Terms and Conditions of Sale and Owner’s 

Manual are shipped with each unit and, if another copy is needed, replacement copies can be downloaded 

from the company website (CellarCool.com) or by contacting CellarCool directly for a new copy. CellarCool 

reserves the right, in its sole discretion, to change its Terms and Conditions at any time, for any reason, 

without notice.

2. CellarCool Product Limited Warranty:

A. Two (2) Year Limited Warranty.  For the period of TWO (2) YEARS (the “Limited Warranty Period”) from the 

date of original sale of a Product by CellarCool, if a CellarCool Product is found to be defective in material or 

workmanship after undergoing CellarCool’s customer service troubleshooting, then, subject to the CellarCool 

Product Limited Warranty Limitations and Exclusions as well as the other Terms and Conditions stated herein, 

CellarCool will do the following, as appropriate, for the end user (“End User”) who has installed and is actually 

using the Product, with regard to LABOR, PARTS and FREIGHT: 

1. LABOR - repair or replace (at CellarCool’s sole option) the Product to the End User; and 
2. PARTS – supply to the End User, new or rebuilt replacement parts for the Product in exchange for the 

return of defective parts; and 
3. FREIGHT – cover normal ground freight charges for parts, and, in the event the Product is not repairable 

in the field, cover normal ground freight charges (within the continental United States) for the repair or 

replacement of the Product.  

B.  Five (5) Year Compressor Limited Warranty.   CellarCool Products’ compressor only will be covered for five (5) 

years from date of purchase.  Labor and freight of the compressor is the End Users responsibility.  

C.  Product Warranty Limitations and Exclusions.  

1.  This limited warranty does not cover cosmetic damage caused during installation, damage due to acts 

of God, commercial use, accident, misuse, abuse, negligence, or modification to any part of the Product.  

Delivery and installation of the Product, any additional parts required, as well as removal of the Product 

if warranty work is required, are all at the sole cost, risk and obligation of the End User.

2.  This limited warranty does not cover damage due to improper installation or operation or lack of proper 

maintenance of the Product, connection of the Product to improper voltage supply, or attempted repair 

of the Product by anyone other than a technician approved by CellarCool to service the Product. 

3.  This limited warranty does not cover any Product sold “AS IS” or “WITH ALL FAULTS.” 
4.  Product that has been replaced during warranty period does not extend the warranty period past the 

original date of purchase. 

5.  (5) This limited warranty is valid only in the continental United States.   Sales elsewhere are excluded 

from this warranty.

6.  Proof of purchase of the Product in the form of a bill of sale, receipted invoice or serial number, which is 

evidence that the Product is within the Limited Warranty Period, must be presented by the End User to 

CellarCool in order to obtain limited warranty service. 

7.  This limited warranty is void if the factory applied serial number has been altered or removed from the 

Product. 

This limited warranty is voided if installed in an enclosure of insufficient design that does 

not follow the Product installation requirements stated herein and in the owner’s manual.

8.  Removing the rivets from the Product’s unit housing without prior authorization from CellarCool 

voids this limited warranty.  

Summary of Contents for cx2200

Page 1: ...CX SERIES OWNER S MANUAL cx2200 cx3300 cx4400 cx8800...

Page 2: ...not responsible for printing or clerical errors CellarCool reserves the right to make corrections or improvements to the information provided and to the related hardware at any time without notice Vi...

Page 3: ...tallation Airflow Control 9 Preparing the Installation Location 10 Preparing the Unit for Installation 11 Installing the System 11 Drain Line 13 System Operation 14 Controller Functions 15 Wiring Sche...

Page 4: ...ool cooling unit is a specialized refrigeration unit designed for one purpose only to maintain the optimal temperature and humidity levels conducive to the proper storage and aging of fine wines It is...

Page 5: ...of the cellar over time by cycling cooler air throughout Test the unit prior to installation 5 You are required to install a drain line to remove condensation from the unit 6 The CellarCool unit is in...

Page 6: ...utlet Power surges and spikes can damage sensitive electrical equipment CellarCool recommends plugging the unit into a surge protector or power conditioner in order to protect your system As outlined...

Page 7: ...5 CX SERIES QUICK REFERENCE GUIDE Front Side View Rear Side View Controller Power cord front location standard ON OFF switch for 4400 8800 models only Power cord rear location optional Air sensor Rear...

Page 8: ...s parts and labor 5 years compressor Sizing the Unit to the Room The specification chart will provide information on the unit s cooling capacity There are circumstances in which a cellar design may re...

Page 9: ...ly use CellarCool products It is vital that all walls and ceilings be insulated to keep the cellar temperature as consistent as possible during the summer and winter months Standard fiberglass or rigi...

Page 10: ...rtion of the unit NOTE High humidity significantly increases the heat load on the cooling system Any break in the vapor barriers a cut a nail hole overlapping etc will cause a moisture leak and must b...

Page 11: ...will best suit your installation NOTE Do not cover both of the openings on the same side of the unit for any reason This will cause cooling issues and premature failure NOTE Do not cover both of the...

Page 12: ...rough your studs when you have a clear understanding what is inside the wall Now make the second horizontal cut from stud to stud on the line below the first cut Once the horizontal lines have been cu...

Page 13: ...ellar Note If you use decorative moulding it should be attached to the walls and never to the cooling unit itself The moulding itself should be removable incase the unit needs servicing Applying Insul...

Page 14: ...n each side of the side of the unit you will notice 6 indents these mark two different installation depths Select one of the two mounting depths and attach each mounting bracket to the unit with the s...

Page 15: ...s important that the drain line tube be properly connected and used to prevent leakage and other problems associated with excess condensation Failure to use the condensation drain line tube will void...

Page 16: ...has reached the setpoint to allow the pressure in the refrigeration unit to equalize prior to starting the compressor Anti Frost Cycle defrost After two hours of compressor operation the controller w...

Page 17: ...utton once more Use the UP and DOWN ARROW buttons in order to change the value until the desired setpoint is reached Hold the set button for approximately 5 seconds to enter the CPSM Customer Preferen...

Page 18: ...snowflake symbol will not be lit 2 Add heat to the room until the wine reaches the desired temperature Press and hold the SET button for approximately 5 seconds to enter the CPSM menu Use the DOWN AR...

Page 19: ...www cellarcool com Page 17 CX SERIES cx2200 cx3300 CONTROLLER WIRING SCHEMATIC Cond Fan Compressor Cond Fan Evap Fan Evap Fan...

Page 20: ...Page 18 1 855 235 5271 CX 040418 cx4400 CONTROLLER WIRING SCHEMATIC Cond Fan Compressor Cond Fan Evap Fan Evap Fan...

Page 21: ...www cellarcool com Page 19 CX SERIES cx8800 CONTROLLER WIRING SCHEMATIC Cond Fan Compressor Cond Fan Evap Fan Evap Fan...

Page 22: ...Page 20 1 855 235 5271 CX 040418 NOTES...

Page 23: ...ine voltage is incorrect rating for unit Check line voltage to make sure there is 110V 120V Room at setpoint Lower setpoint Thermostat not calling for cooling Lower setpoint Faulty thermostat or wirin...

Page 24: ...Solution Lack of airflow heat exhaust outer room Make sure fan is unobstructed clean evaporator if necessary The unit is undersized for the room Purchase correctly sized unit Evaporator fan runs but...

Page 25: ...USING INTERIOR DRAIN LINE Insert supplied drain line brush from this end Drop pan tab into drip tray through access door ACCESS DOOR CX2200 ACCESS DOOR CX3300 4400 8800 ACCESS DOOR SCREWS REAR OF UNIT...

Page 26: ...arCool Customer Service 1738 E Alpine Ave Stockton CA 95205 www cellarcool com Email support cellarcool com Tech Support Customer Service 1 800 343 9463 Sales Sizing Assistance 1 855 235 5271 Fax 209...

Page 27: ...d in the event the Product is not repairable in the field cover normal ground freight charges within the continental United States for the repair or replacement of the Product B Five 5 Year Compressor...

Page 28: ...arCool Owner s Manual and thereafter the End User must follow the required installation use and maintenance procedures set forth by CellarCool in CellarCool s Owner s Manual The Owner s Manual is ship...

Page 29: ...t 1738 East Alpine Avenue Stockton California 95205 8 Miscellaneous Terms and Conditions A Return Policy All return inquiries must be made within thirty 30 calendar days of the original purchase of a...

Page 30: ...343 9463 or please send a letter via U S Mail to Customer Service CellarCool Corporation 1738 E Alpine Ave Stockton CA 95205 Email support cellarcool com Web www cellarcool com B Technical Assistance...

Page 31: ...CellarCool 1738 E Alpine Ave Stockton CA 95205 1 800 343 9463 www cellarcool com...

Reviews:

Related manuals for cx2200