![Cell2 SW833 Installation & Operation Manual Download Page 9](http://html1.mh-extra.com/html/cell2/sw833/sw833_installation-and-operation-manual_2580253009.webp)
- 8 -
Error Signal
Under Programming Mode 1 or Mode 2, when you program a button with the function cannot
be activated (e.g. B1 has been set as a permanent switch. Configure B3 to activate B1
automatically), an error occurs and the green backlight will flash three times on those buttons
with three “beep” sounds.
Reset to Factory Default Configuration
1. Press B2 and B4 for more than 1 second to enter Programming Mode 2.
2. Press and hold B3 and B4 for more than 5 seconds.
3. If SW833 Controller has been restored to factory default configuration successfully, the
controller will return to operation mode (after “beep” for three times and green backlight is
ON).
Automatic Standby Mode
(default configuration)
Automatically enter Standby Mode after 15 minutes if no buttons are activated and Input 1 is
not activated either.
(Refer to 3-6 Programming Mode 2, p.19, for detailed information of Standby Mode Configu-
ration)
NOTE:
After entering Standby Mode, Programming Mode CANNOT be accessed by default.
If you want to enter Programming Mode, disconnect all power and reboot your SW833
Controller.
Testing Mode
(for factory users only)
1. Enter Programming Mode 2.
2. Press and hold B7 and B8 for more than 3 seconds.
3. Under Testing Mode, you can test the connection of Input 1 / Input 2 / Input 3 respectively.
4. After finishing testing, disconnect all power to exit Testing Mode.
NOTE:
Testing Mode is accessible ONLY under Factory Default Configuration.