Celect CC908-RF Installation And Operation Instructions Manual Download Page 4

 

 

4

SIGNAL RECEIVE/LEARN(YELLOW)

SWITCH AND LED DESCRIPTION OF RECEIVER 

SIGNAL RECEIVE/LEARN(YELLOW)

SIGNAL ON

ON/OFF BUTTON

RXD/LEARN ON

POWER

POWER(RED)

LEARN BUTTON

REMOTE CONTROL

ON/OFF

LEARN

 

                              Figure 4 

Wireless signal confirm 

1)

 

Plug the power switch with 230VAC power, Then the power light will be on(Red). 

2)

 

Long press the button LEARN ,the light RXD/LEARN will on 

Yellow

3)

 

Then load the 2 AA battery into the transmitter.    After five second . Then the yellow light will flash 

in several seconds. When it going out. It states the wireless control between thermostat and the power 

switch established. 

4)

 

Then roll the knob of the transmitter , make the setting temp > room temp , then the heating icon will 

display in the LCD , please check if the receiver plug light change to green . If it is , the 

communication between the transmitter and the receiver plug is working 

OPERATION 

1.

 

Configuration Menu   

  The configuration menu allows you to set certain thermostat operating characteristics to your system 

or personal requirements. Shortly press button 

  to make sure the thermostat is in anti-freeze mode. 

Hold button 

  for 3 seconds to enter the configuration menu. The display will show the first item in the 

configuration menu. Press button 

 

to shift to the next menu item. Use 

 or 

to select. To exit the 

menu , press button 

  revert to the anti-freeze mode . Press button 

  revert to the program operation. 

If no buttons are pressed within 20 second the thermostat will exit the menu. To revert to factory default 

setting , push 

 or 

  button in a same time for 3 seconds. Display will show “DEF” blinking 3 times 

and return to Menu item 1 indicates all the configuration setting has reverted to factory default setting. 

Step Press 

buttons Displayed

factory default

Press

 or 

to select 

Descriptions 

 

01    (0) 

-3 --- +3 

Select temperature display adjustment higher or lower

 

 02 

35

℃)

 18

(64

)—35

(95

Select maximum setting temperature limitation.

 

 03 

5

℃)

 

5

(41

)—20

(68

Select minimum setting temperature limitation.

 

 04 

(℃)

 

/

 

Select temperature display to

℃ or ℉

 

 05 

FA

 

FA/SL 

Select fast heating or slow heating

 

 06 

OO

 

PP/OO 

Select pump protection PP, Cancel pump protection OO 

 07 

24

 

12 or 24 

Selection of time scale 

 

08    (7) 

3or7 

Programming day in one week option 

Special feature 

Intelligent Recovery: See configuration menu item 6- 

Intelligent Recovery operation. 

SELF CHECK FUNCTION : IF THE RECEIVER DID NOT 

RECEIVE THE SIGNAL FROM THE TRANSMITTER FOR 

ONE HOUR, THE RECEIVER WILL POWER ON THE 

HEATER BOILER. AND AFTER 24 HOURS., THE 

RECEIVER STILL NOT RECEIVING THE SINAL . ITS 

YELLOW LIGHT WILL FLASH ALARM THAT THER 

MAYBE SOMETHING WRONG WITH THE 

THERMOSTAT. IF THERE IS A SIGNAL CONTACT. THEN 

THE YELLOW LIGHT STOP FLASHING. AND THE 

THERMOSTAT WILL RUN AS THE SCHEDULE SETTING.

Summary of Contents for CC908-RF

Page 1: ...5 Accuracy 1 or 0 5 Dimensions Control Centre 115mm 90mm 28mm Receiver 126mm 68mm 47mm Color White FEATURE Can be placed anywhere in the home to detect and control the temperature of an area of the user s choice Not limited by power control wiring locations Link with the Receiver via RF Control distance 100M open site Large LCD display The screen displays the set temperature and the room temperatu...

Page 2: ...e product long time not use it please detach the battery prevent the battery fluid leakage damaged products INSTALL THE CONTROL CENTRE Screw for mounting thermostat to wall Base Control panel Fixing screw 1 Remove 2 screws from the bottom of thermostat See Figure 1 Gently pull the control panel straight off the base Forcing or prying on the thermostat will cause damage to the unit 2 Push power bas...

Page 3: ...ing temperature Low battery indicator Shows temperature display in or time to get up time to go out in the morning time to come back in the morning time to go out in the afternoon time to return in the afternoon time to go to bed Low battery indicator System in Anti freezing mode System in heating mode Flashes when there is a call for heating Manual temperature overide operation Program operation ...

Page 4: ...e or to select To exit the menu press button revert to the anti freeze mode Press button revert to the program operation If no buttons are pressed within 20 second the thermostat will exit the menu To revert to factory default setting push or button in a same time for 3 seconds Display will show DEF blinking 3 times and return to Menu item 1 indicates all the configuration setting has reverted to ...

Page 5: ... PP will activate pump protection mode Select OO will cancel the function it shows heating out normally When thermostat activating the pump 15 in the display will blink Heating output will be automatic operated as your setting 7 Time display To select 12 hours or 24hours display 8 There are 2 options for how to program the day in one week 7 You can program in 7 individual days Factory default is 7...

Page 6: ...ither or until you reach the correct hour and AM or PM designation AM begins at night PM begins at noon 3 Press button once again The display will only show minutes flashing 4 Press and hold either or until you reach the correct minutes 5 Press button once again The display will show the day of the week flashing 6 Press or until you reach the correct day of the week Press button once The display w...

Page 7: ...ogrammed each day 7 Press once 2 indicating Tuesday program will appear in the display along with the start time for the 1st heating period and the currently programmed temperature If the display shows 6 indicating that Saturday program will be modified in 5 1 1 day model 8 Repeat steps 3 through 6 to complete Tuesday 7 day model or Saturday 5 1 1 day model heating programming 9 Continue entering ...

Page 8: ...8 ...

Reviews: