background image

1. GENERAL INFORMATION

1.1. WARRANTED INFORMATION

CEL-MAR Company

  gives a two-year warranty on the  

DES-300E sensor.

   The warranty does not cover damage caused from

improper   use,   materials   consumption  or   any   unauthorized   changes.   If   the   product   does   not   function   in   accordance   with   the

instructions, will be repaired or replaced.
All warranty and no warranty repairs must be returned with paid transport and insuring to the 

CEL-MAR Company.

CEL-MAR Company 

under no circumstances won't be responsible for ensuing damage from improper using the product or as a result

of random causes: the lightning discharge, the flood, the fire and the like.

CEL-MAR Company

 is not be held responsible for damages and loss including: loss of profits, loss of data, pecuniary losses ensuing

from using or the impossibility of using this product.
In specific cases 

CEL-MAR Company

 discontinue all warranties and in particular do not follow the user manual and do not accept

terms of warranty by the user

1.2. GENERAL CONDITIONS FOR SAFE USE

The device should install in the safe and stable place, the connecting cable should be arranged this way isn't exposed to treading,

catching or tear out from sensor

Do not put device on the wet surface.

Do not connect devices for nondescript powering sources,

Do not damage or crush powering wires.

Do not make connection with wet hands.

Do not adapt, open or make holes in casings of the device!

Do not immerse device in water or no other liquid.

Do not put the fire opened on device sources: candles, an oil lamps and the like.

1.3. CE LABEL

CE symbol on organizing the company CEL-MAR a conformity of the device to the directive of the electromagnetic  

EMC

2014/30/WE

  (Electromagnetic   Compatibility  Directive).   The   declaration   of   the   agreement   is   accessible   through   the

contact with the technical service at the address e-mail: [email protected] or on the phone at the +48 41 362-12-46. 

1.4. ENVIRONMENTAL PRESERVATION

This sign on the device inform about putting expended device with other waste materials. Device should send to the

recycling. (In accordance with the act about the Electronic Appliance Expended from day 29 of July 2005)

1.5. SERVICE AND CONSERVATION

It is recommended to check the status of cases and sensor connecting cables, to eliminate the effect of mechanical damage on the

quality of measurement.

Technical support at the number: +48 41 362-12-46 in 8.00-16.00, from Monday to Friday

1.6. PACK CONTENTS

The sensor is delivered with: user manual,

2. APPLICATION

DES-300E sensor is used for measurement of environmental parameters like temperature, relative humidity, illumination, sunlight in:

offices with the use of structured cabling

flats

houses

via the serial 1-WIRE Bus.

Application of 1-Wire bus enables:

the cooperation of many sensors connected to the same data lines,

the deployment of sensors in various locations up to 300m,

powering the sensors from the bus,

correct transmission of measurement data secure check sum CRC.

DES-300 sensor can be installed on wiring recessed cans or on the walls.

3

DES-300E

Summary of Contents for DES-300E

Page 1: ...User manual DES 300E Digital environmental parameters sensor 1 io_des 300e_v1 00_en DES 300E Copyright 2001 2017 CEL MAR sp j...

Page 2: ...2 APPLICATION 3 3 COOPERATION WITH OTHER 1 WIRE DEVICES 4 4 VIEW OF SENSOR 4 5 CONNECTION OF 1 WIRE BUS 5 5 1 CONNECTION TO 1 WIRE BUS SENSOR POWER SUPPLY FROM ADA 401WP 5 5 1 1 EXAMPLE OF CONNECTION...

Page 3: ...merse device in water or no other liquid Do not put the fire opened on device sources candles an oil lamps and the like 1 3 CE LABEL CE symbol on organizing the company CEL MAR a conformity of the dev...

Page 4: ...toring and control systems for environmental parameters ADA 401WP Measuring Module 1 WIRE to MODBUS RTU DNB 400 Passive 1 WIRE Bus Splitter DNB 215 Passive 1 WIRE Bus Splitter DNB 200 Passive 1 WIRE B...

Page 5: ...nect the bus to terminal block described as below 5V powering the bus 5VDC 1 W 1 WIRE data transmission GND signal ground b after connection 1 WIRE bus to terminals 5V 1 W GND of DES 300E set the S1 s...

Page 6: ...S485 MODBUS ADA I1040 ADAI9140 DES 300E T GND Rx 1 W VDD L RS232 USB RS485 MODBUS PE GND Tx B Tx A Rx GND Rx RS232 USB Vss Vss Unused twisted pair cables are connected together and connected to PE ele...

Page 7: ...owering from additional power supply 1 W data transmission 1 WIRE GND signal ground b after connection 1 WIRE bus to terminals 12VDC 1 W GND of DES 300E set the S1 switch to 12V position Not applicabl...

Page 8: ...S PE GND Tx B Tx A Rx GND Rx RS232 USB Vss Vss 230V V N V 12V ADA 401WP DES 300E T H DES 300E T H GND NC VDD 12V 1 W GND NC VDD 12V 1 W GND NC VDD 12V 1 W Computer with Free SCADA or PLC with support...

Page 9: ...s 0 06 C Parameters of Humidity Sensor Measuring range of relative humidity 0 100 RH Measuring accuracy of relative humidity 3 50 RH Parameters of Lighting Sensor Measuring range of lighting 0 100 Lux...

Page 10: ...10 DES 300E...

Page 11: ...11 DES 300E...

Page 12: ...c Converters 1 Wire ETHERNET Wi Fi digital sensors as temperature humidity pressure illumination power supply Please express your opinion by e mail or phone on this product and advise us how we can sa...

Reviews: