background image

1. GENERAL INFORMATION

1.1. WARRANTED INFORMATION 

CEL-MAR Company

 gives a two-year warranty on the 

DES-300 sensor.

  The warranty does not cover damage caused from improper

use, materials consumption or any unauthorized changes. If the product does not function in accordance with the instructions, will be

repaired or replaced.
All warranty and no warranty repairs must be returned with paid transport and insuring to the 

CEL-MAR Company.

CEL-MAR Company 

under no circumstances won't be responsible for ensuing damage from improper using the product or as a result

of random causes: the lightning discharge, the flood, the fire and the like.

CEL-MAR Company

 is not be held responsible for damages and loss including: loss of profits, loss of data, pecuniary losses ensuing

from using or the impossibility of using this product.
In specific cases 

CEL-MAR Company

 discontinue all warranties and in particular do not follow the user manual and do not accept

terms of warranty by the user

1.2. GENERAL CONDITIONS FOR SAFE USE

The device should install in the safe and stable place, the connecting cable should be arranged this way isn't exposed to treading,

catching or tear out from sensor

Do not put device on the wet surface.

Do not connect devices for nondescript powering sources,

Do not damage or crush powering wires.

Do not make connection with wet hands.

Do not adapt, open or make holes in casings of the device!

Do not immerse device in water or no other liquid.

Do not put the fire opened on device sources: candles, an oil lamps and the like.

1.3. CE LABEL

CE symbol on organizing the company CEL-MAR a conformity of the device to the directive of the electromagnetic  

EMC

2014/30/WE

  (Electromagnetic   Compatibility   Directive).   The   declaration   of   the   agreement   is   accessible   through   the

contact with the technical service at the address e-mail: [email protected] or on the phone at the +48 41 362-12-46. 

1.4. ENVIRONMENTAL PRESERVATION

This sign on the device inform about putting expended device with other waste materials. Device should send to the

recycling. (In accordance with the act about the Electronic Appliance Expended from day 29 of July 2005)

1.5. SERVICE AND CONSERVATION

It is recommended to check the status of cases and sensor connecting cables, to eliminate the effect of mechanical damage on the

quality of measurement.

Technical support at the number: +48 41 362-12-46 in 8.00-16.00, from Monday to Friday

2. APPLICATION

DES-300 sensor is used to for measurement of environmental parameters like temperature, relative humidity, atmospheric pressure,

illumination, concentration of CO2  in :

offices with the use of structured cabling

flats

houses

via the serial 1-WIRE Bus.

Application of 1-Wire bus enables:

the cooperation of many sensors connected to the same data lines,

the deployment of sensors in various locations up to 300m,

powering the sensors from the bus,

correct transmission of measurement data secure check sum CRC.

DES-300 sensor can be installed on wiring recessed cans or on the walls.

3

DES-300

Summary of Contents for DES-300

Page 1: ...User manual DES 300 Digital environmental parameters sensor 1 io_des 300_en_v0 21 DES 300 Copyright 2001 2018 CEL MAR sp j ...

Page 2: ...DES 300 TTA 5 6 VIEW OF RELATIVE HUMIDITY SENSOR WITH PERCENT ADJUSTER DES 300 HPA 5 7 CONNECTION OF 1 WIRE BUS 6 7 1 POWERING THE SENSORS FROM THE MODULE ADA 401WP 7 7 1 1 EXAMPLE CONNECTION OF SENSORS 8 7 2 POWERING THE SENSORS FROM THE MODULE ADA 401WP AND 12VDC POWER SUPPLY 9 7 2 1 EXAMPLE CONNECTION OF SENSORS 10 8 PARAMETERS AND CONFIGURATION OF PIR SENSOR 11 8 1 PIR SENSOR PARAMETERS 11 8 2...

Page 3: ...ice Do not immerse device in water or no other liquid Do not put the fire opened on device sources candles an oil lamps and the like 1 3 CE LABEL CE symbol on organizing the company CEL MAR a conformity of the device to the directive of the electromagnetic EMC 2014 30 WE Electromagnetic Compatibility Directive The declaration of the agreement is accessible through the contact with the technical se...

Page 4: ...itoring and control systems for environmental parameters ADA 401WP Measuring Module 1 WIRE to MODBUS RTU DNB 400 Passive 1 WIRE Bus Splitter DNB 215 Passive 1 WIRE Bus Splitter DNB 200 Passive 1 WIRE Bus Splitter other 1 WIRE sensors eg DTS RJ45 DTS 103 DTS 107 DES 200 DES 216 DES 300 4 VIEW OF SENSOR 4 DES 300 ...

Page 5: ...5 VIEW OF TEMPERATURE SENSOR WITH TEMPERATURE ADJUSTER DES 300 TTA 6 VIEW OF RELATIVE HUMIDITY SENSOR WITH PERCENT ADJUSTER DES 300 HPA 5 DES 300 8cm 8cm ...

Page 6: ...the bus you should a by the use of small screwdriver disassemble the rear panel as shown below b by the use of small screwdriver removed from the cover the PCB as shown below c insert the wires of 1 WIRE BUS through the holes of rear panel and PCB as shown below 6 DES 300 ...

Page 7: ...he rear panel of sensor on electro installation box or a wall insert the PCB to the cover terminals to inside or insert DS18B20 with screw terminal block in case of DES 300 TE sensor put the cover on rear panel 7 DES 300 Unused cables can be connect ed together clamp the tubular tip and insulated 12VDC NC DQ 1 W GND VDD If other lines are not used can be combined together and insulate for keeping ...

Page 8: ...d power supply 10 24 VDC 1 WIRE RS485 MODBUS ADA I1040 ADAI9140 GND Rx 1 W VDD L RS232 USB RS485 MODBUS PE GND Tx B Tx A Rx GND Rx RS232 USB Vss Vss 230V V N V 10 24V ADA 401WP DES 300 T RS485 2W Up to 1200m Cable UTP 4x2x0 5 DQ GND VDD DQ GND VDD DQ GND VDD DQ GND VDD DQ GND VDD DQ GND VDD DES 300 H DES 300 H DES 300 T DES 300 T DES 300 T ...

Page 9: ...OT connect the power VDD from the ADA 401WP module to VDD terminal block of DES 300 sensor Connection may damage the ADA 401WP module b after connection 1 WIRE BUS to terminals 12VDC DQ GND set the PWR switch to 12V position fix the rear panel of sensor on electro installation box or a wall insert the PCB to the cover terminals to inside put the cover on rear panel 9 DES 300 12VDC NC DQ 1 W 12VDC ...

Page 10: ... VDD NC GND DES 300 T H DQ VDD DS18B20 12VDC Tx B Tx A Rx Stable power supply 12 VDC 10W DR 15 12 1 WIRE RS485 MODBUS GND Rx 1 W VDD L PE GND Vss Vss 230V V N V 12V ADA 401WP ADA I1040 ADAI9140 RS485 MODBUS Tx B Tx A Rx GND Rx RS232 USB RS485 2W Up to 1200m Computer with FreeSCADA software or PLC with support of MODBUS protocol RS 232 USB ...

Page 11: ...ENSOR 8 1 PIR SENSOR PARAMETERS Parameters Value Measurement range max 7 m Viewing angle Up to 100 Alarm output OUT State High object detected 3 3VDC State Low no object 0VDC Operating temperature from 15 C to 70 C Operating range 11 DES 300 ...

Page 12: ... OUTPUT reaches high state only once after detecting an object then goes to Low state regardless of whether there is further movement 9 VERSIONS DES 300 x x x x The basic sensor types can be mixed together except CO2 sensor Order example Product symbol DES 300 T H T H temperature and relative humidity Product symbol DES 300 T H AP T H AP temperature and relative humidity and atmospheric pressure S...

Page 13: ...dity Sensor Measuring range of relative humidity 0 100 RH Measuring accuracy of relative humidity 3 50 RH Operating temperature 40 C 85 C Parameters of Atmospheric Pressure Sensor Measuring range of atmospheric pressure 150 hPa 1150 hPa Measuring accuracy of atmospheric pressure 15 hPa Operating temperature 40 C 85 C Parameters of Temperature Adjuster Range of temperature adjuster 5 C 40 C Accurac...

Page 14: ...ation 0 5000 ppm Measuring accuracy of CO2concentration 50 ppm 3 readout Operating temperature 0 C 50 C General Parameters Supply voltage From 1 WIRE bus VDD 5VDC or from 12VDC stable power supply Max power 10mW 600mW depend on version Protection from reverse power polarization YES Warning for reverse power on is shorted VDD to GND Bus cabling Recommended UTP 4x2x0 5 AWG24 twisted cable Cover oper...

Page 15: ...15 DES 300 ...

Page 16: ...ic Converters 1 Wire ETHERNET Wi Fi digital sensors as temperature humidity pressure illumination power supply Please express your opinion by e mail or phone on this product and advise us how we can satisfy you present and future of expecting CEL MAR sp j Computers Science and Electronic Factory str Sciegiennego 219C 25 116 Kielce Poland Tel 48 41 362 12 46 Tel fax 48 41 361 07 70 Web http www cel...