Table 1. The straight cable for connection to switch or hub.
RJ45 Pin
No.
Signal
Wire Color
EIA/TIA 568B
Straight cable
UTP 4x2x0,5
Wire Color
EIA/TIA 568B
Signal
RJ45 Pin
No.
1
TX+
White-Orange
2
TX-
Orange
3
RX+
White-Green
4
Not used
Blue
5
Not used
White-Blue
6
RX-
Green
7
Not used
White-Brown
8
Not used
Brown
White-Orange
TX+
1
Orange
TX-
2
White-Green
RX+
3
Blue
Not used
4
White-Blue
Not used
5
Green
RX-
6
White-Brown
Not used
7
Brown
Not used
8
The table below shows preparing of cross-over cable for the converter connection to PC network adapter or connections converters
together for functioning as point-to-point serial bridge.
Table 2. The cross-over cable for connection to PC network adapter or connections converters together for functioning as
point-to-point serial bridge.
RJ45 Pin
No.
Signal
Wire Color
EIA/TIA 568B
Cross-Over Cable
UTP 4x2x0,5
Wire Color
EIA/TIA 568B
Signal
RJ45 Pin
No.
1
TX+
White-Orange
2
TX-
Orange
3
RX+
White-Green
4
Not used
Blue
5
Not used
White-Blue
6
RX-
Green
7
Not used
White-Brown
8
Not used
Brown
White-Green
TX+
1
Green
TX-
2
White-Orange
RX+
3
Blue
Not used
4
White-Blue
Not used
5
Orange
RX-
6
White-Brown
Not used
7
Brown
Not used
8
In the modular socket ETHERNET interface of converter, are implemented two LED's (Fig. 1):
–
Green ACT signalling state of sending or receiving data,
–
Orange LINK signalling active network connection.
ADA-13110MG converter can function in the ETHERNET network as:
–
virtual serial bridge [RealPort],
–
TCP serial bridge,
–
UDP serial bridge.
Additional information about Ethernet connection will be describe in chapters below.
3.2.1. CONNECTING TO NETWORK ADAPTER OF PC
If there is not the switch or the HUB, it is possible to connect the ADA-13110MG directly to a network adapter of PC using the cross-
over cable (Table 2). This connection can be used for converter configuration.
Fig. 3. Direct connection to PC
3.2.2. CONNECTING FOR OPERATING IN REALPORT MODE
Figures 3 (above) and 4, 5 (below) show how correctly connect the ADA-13110MG to LAN, WAN network or PC, for operating in
virtual serial port mode (RealPort).
For direct connection of the converter to PC network adapter, use the cross-over cable (see Table 2) and for connection by the use of
switch or HUB use the straight cable (see Table 1).
7
ADA-13110MG
PC with a network
adapter
Static IP address
ADA-13110MG
Static IP address
ETHERNET
Crossover cable
(Table 2)