background image

1. GENERAL INFORMATION

Thank you for your purchase of 

CEL-MAR Company

 product. This product has been completely tested and is covered by a two year

warranty on parts and operation from date of sale. 
If any questions or problems arise during installation or use of this product, please do not hesitate to contact Technical Support at +48

41 362-12-46 or e-mail [email protected].

1.1. WARRANTED INFORMATION 

ADA-13021MG  

converter is covered by a two year warranty from date of sale.   In case of being damaged it will be repair or the

damaged component will be replace. The warranty does not cover damage caused from improper use, materials consumption or any

unauthorized changes. If the product does not function (is damaged), or not operate in accordance with the instructions, will be

repaired.
All warranty and no warranty repairs must be returned with paid transport and insuring to the 

CEL-MAR Company.

CEL-MAR Company 

under no circumstances won't be responsible for ensuing damage from improper using the product or as a result

of random causes: the lightning discharge, the flood, the fire and the like.

CEL-MAR Company

 is not be held responsible for damages and loss including: loss of profits, loss of data, pecuniary losses ensuing

from using or the impossibility of using this product.
In specific cases

 CEL-MAR Company

 discontinue all warranties and in particular do not follow the user manual and do not accept

terms of warranty by the user.  

1.2. GENERAL CONDITIONS FOR SAFE USE

The device should be installed in a safe and stable places (eg, electroinstallation cabinet), the powering cable should be arranged  so

as not to be exposed to trampling, attaching, or pulling out of the circuit. 

Do not put device on the wet surface.

Do not connect devices for nondescript powering sources,

Do not damage or crush powering wires.

Do not make connection with wet hands.

Do not adapt, open or make holes in casings of the device!

Do not immerse device in water or no other liquid.

Do not put the fire opened on device sources: candles, an oil lamps and the like.

Complete disable from the supply network is only after disconnecting the power supply circuit voltage. 

Do not carry out the assembly or dis-assembly of the device if it is enabled. This may result to short circuit and damage the device.

The device can not be used for applications that determine human life and health (eg. Medical).

1.3. CE LABEL

The   CE   symbol   on   the   device   CEL-MAR   means   compatibility   with   electromagnetic   compatibility   Electromagnetic
Compatibility   Directive  

EMC   2014/30/WE.

  Declaration   of   Conformity  is   available   by   contact   with   Technical   Service

(email: [email protected]; phone: +48 41 362-12-46).

1.4. ENVIRONMENTAL PRESERVATION

This sign on the device inform about putting expended device with other waste materials. Device should send to the

recycling. (In accordance with the act about the Electronic Appliance Expended from day 29 of July 2005)

1.5. SERVICE AND MAINTENANCE

ADA-13021MG converter does not require the servicing and maintenance.

Technical support is available at 48 41 362-12-46 in 8.00-16.00, from Monday to Friday or e-mail 

[email protected]

.

1.6. PACK CONTENTS

The converter is delivered with the user manual and CD-ROM with ADANet software.

2. PRODUCT INFORMATION

2.1. PROPERTIES

Operating on ETHERNET network- IEEE 802.3 standard,

10/100BaseT physical layer,

Connecting via Rj45 connector, 

Baud rate 10/100Mbps (auto-sensing),

Full or half duplex (auto-sensing) operate modes,

Protocols: TCP, UDP, DHCP, SNMP, SSL/TLS, Telnet, Rlogin, LPD, HTTP/HTTPS, SMTP, ICMP, IGMP, ARP,

Integrated WWW sever for converter configuration,

Configuration of net services according to user personal setting,

Static or dynamic IP address (added by DHCP server),

Diagnostics of serial and network port,

Encoded transmission: DES (56-bit), 3DES (168-bit), AES (128/256-bit),

Operating modes: virtual serial port, serial bridge TCP, serial bridge UDP, TCP sockets, UDP sockets, MODBUS Data Gateway,

Operating on 4-wire line in Current Loop standard,

Current Loop baud rates (bps):  50, 75, 110, 134, 150, 200, 300, 600, 1200, 1800, 2400, 4800, 9600, 14400, 19200, 28800, 

38400,

Current Loop data format - Number of data bits: 5, 6, 7, 8; Parity checking: None, Odd, Even, Constantly 1, Constantly 0; Stop Bits:

4

ADA-13021MG

Summary of Contents for ADA-13021MG

Page 1: ...User manual ADA 13021MG Current Loop to ETHERNET converter with MODBUS GATEWAY 1 io_ada 13021mg_v1 01_en ADA 13021MG Copyright 2001 2018 CEL MAR sp j ...

Page 2: ...AFINDER SOFTWARE 14 5 1 1 ADAFINDER INSTALLATION 14 5 1 2 NETWORK SETTING 14 5 2 CONFIGURATION AND MANAGEMENT BY THE USE OF INTERNET BROWSER 16 5 2 1 NETWORK CONFIGURATION 16 5 2 2 SERIAL PORT CONFIGURATION 17 5 2 2 1 SERIAL PORT PROFILE CONFIGURATION OPERATING MODE 17 5 2 2 1 1 REALPORT VIRTUAL PORT CONFIGURATION 18 5 2 2 1 2 TCP SOCKETS CONFIGURATION 18 5 2 2 1 2 1 TCP SERVER CLIENT CONFIGURATIO...

Page 3: ...8 5 2 6 7 LOGOUT ENDING MANAGEMENT AND CONFIGURATION 28 6 USING VIRTUAL PORT SERVICE REALPORT 28 6 1 VIRTUAL PORT DRIVER INSTALLATION IN WINDOWS XP 28 6 2 REALPORT CONFIGURATION IN WINDOWS XP 28 7 FACTORY DEFAULT 30 8 TROUBLESHOOTING 30 9 VERSIONS 30 10 SPECIFICATION 31 3 ADA 13021MG ...

Page 4: ...rces candles an oil lamps and the like Complete disable from the supply network is only after disconnecting the power supply circuit voltage Do not carry out the assembly or dis assembly of the device if it is enabled This may result to short circuit and damage the device The device can not be used for applications that determine human life and health eg Medical 1 3 CE LABEL The CE symbol on the d...

Page 5: ...lock for connecting the Current Loop interface and power supply and RJ45 modular connector for ETHERNET network connection The converter transmits data via Current Loop interface with maximum baud rate up to 38 4 kbps and uses signals RX RX TX TX of CL interface To Current Loop line based on ADA 13021MG can be connected in point to point topology devices operate in half duplex or full duplex mode ...

Page 6: ...4 CURRENT LOOP INTERFACE 2 4 1 CURRENT LOOP TRANSMITTER The Current Loop transmitter in ADA 13021MG was made as a passive 0 20mA TTY having low energy short circuit protection on TX and TX lines By the correct connection of the transmitter with power source I1 Current Loop transmitter 0 20mA can operate as active The transmitter diagram is shown on figure below 2 4 2 CURRENT LOOP RECEIVER ADA 1302...

Page 7: ...EIA TIA 568B Straight cable UTP 4x2x0 5 Wire Color EIA TIA 568B Signal RJ45 Pin No 1 TX White Orange 2 TX Orange 3 RX White Green 4 Not used Blue 5 Not used White Blue 6 RX Green 7 Not used White Brown 8 Not used Brown White Orange TX 1 Orange TX 2 White Green RX 3 Blue Not used 4 White Blue Not used 5 Green RX 6 White Brown Not used 7 Brown Not used 8 The table below shows preparing of cross over...

Page 8: ...o operating in virtual serial port mode RealPort For direct connection of the converter to PC network adapter use the cross over cable see Table 2 and for connection by the use of switch or HUB use the straight cable see Table 1 Fig 6 The LAN connection via switch hub to operating in the Real Port mode 8 ADA 13021MG PC with a network adapter Static IP address ETHERNET Crossover cable Table 2 ADA 1...

Page 9: ...operating in the TCP UDP serial bridge mode one to one 9 ADA 13021MG Device with Current Loop interface Current Loop INTERNET ROUTER Public IP address ROUTER Public IP address ETHERNET Straight Cable Table 1 PC with a network adapter Static IP address ETHERNET Straight Cable Table 1 ADA 13021MG Static IP address Current Loop Current Loop ETHERNET Straight Cable Table 1 Local network ETHERNET built...

Page 10: ...RNET Straight cable Table 1 Current Loop SLAVE Device with Current Loop interface MASTER Device with Current Loop interface Current Loop Current Loop SLAVE Device with Current Loop interface ADA 13021MG Static IP address ADA 13021MG Static IP address ADA 13021MG Static IP address ETHERNET Straight cable Table 1 ETHERNET Straight cable Table 1 ...

Page 11: ...ion allows integrating MODBUS TCP devices and MODBUS RTU ASCII devices in one network Fig 10 Integration of Modbus TCP MODBUS RTU ASCII into a single network using ADA 13110MG with MODBUS Gateway 11 ADA 13021MG Current Loop MODBUS RTU ASCII SWITCH ETHERNET PC with SCADA HMI software ADA 13021MG MODBUS Gateway ADA 130210MG MODBUS Gateway Current Loop MODBUS RTU ASCII PLC MASTER LAN ETHERNET LAN net...

Page 12: ...ECEIVER Fig 12 Example connection of device with active transmitter and active receiver to ADA 13021MG 12 ADA 13021MG ADA 13021MG Passive Transmitter Vss Vss Power supply ETH V V Tx Tx Rx Rx Current Loop Device I1 I1 I2 I2 Rx ETHERNET connector Passive Receiver Current Loop connector Transmitter Receiver Tx Tx Rx Current Loop connector ADA 13021MG Active Transmitter Vss Vss ETH V V Tx Tx Rx Rx I1 ...

Page 13: ... 24 Power cable from DC power supplies to device must not be longer than 3m Observe the polarity connect positive of DC power supplies to V and negative end to V terminal ADA 13021MG has the protection from opposite connection power supply 13 ADA 13021MG ADA 13021MG Vss Vss ETH V V Tx Tx Rx Rx I1 I1 I2 I2 Rx Tx Tx Rx Current Loop Device Power supply ETHERNET connector Current Loop connector Transm...

Page 14: ...After installation the software ADAFinder and ADAWiz are available in Start Programs CEL MAR ADANet 5 1 2 NETWORK SETTING ADAFinder is use for initial configuration of converter s network setting Before running ADAFinder should be disabled the System FireWall After running the program is searching local network and if find ADA 13021MG will add them to the list of available converters Devices Fig 1...

Page 15: ...Fig 15 Base configuration network by the use ADAFinder software Fig 16 ADAFinder configuration of IP network address 15 ADA 13021MG ...

Page 16: ...elow Fig 17 The web page for configuration and management of ADA 13021MG 5 2 1 NETWORK CONFIGURATION To make changes of default setting or new configuration of ADA 13021MG select on left panel Configuration Network and then on right IP Settings Fig 17 and make the selection Obtain an IP address automatically using DHCP or Use the following IP address in this option enter IP Address of the converte...

Page 17: ...open the configuration details page includes Port Profile Settings Basic Serial Settings Advanced Serial Settings 5 2 2 1 SERIAL PORT PROFILE CONFIGURATION OPERATING MODE Select on right panel Serial Port Configuration Port Profile Settings and then press Change Profile will open the page Select Port Profile for selection of available port profiles fig 19 Configuration of profile used in typical s...

Page 18: ...sage 5 2 2 1 2 TCP SOCKETS CONFIGURATION Choosing TCP Sockets is configured the serial port of ADA 13021MG for direct communication with PC or other network device by the use of TCP socked Data sending by application device to TCP socked are transferred through network to ADA 13021MG converter and are present on his serial port To save selected configuration press the button Apply 5 2 2 1 2 1 TCP ...

Page 19: ...l port service is 2101 If on the local network is conflict with other network service using the same port in the converter s port configuration change number of port into another for the server and client service 5 2 2 1 2 2 THE ENABLE TCP KEEP ALIVE OPTION CONFIGURATION Option Enable TCP Keep Alive keeps connection between server and client even if the data is not transmitted over the network and...

Page 20: ...kets profile will open section UDP Server Settings with operating parameters like on picture below Set access to UDP server on e g 2101 port Then select Automatically send serial data in section UDP Client Settings this automatically send received data by the use UDP client service to the SLAVE device connected to LAN WAN through e g ADA 13021MG ADA 13040 ADA 13110 ADA14040 ADA 14040 On lists Send...

Page 21: ...ing the configuration of UDP client and server for SLAVE device press Apply Fig 23 Example configuration of the UDP server client on converter connected to SLAVE device ATTENTION Default port of serial port service is 2101 If on the local network is conflict with other network service using the same port in the converter s port configuration change number of port into another for the server and cl...

Page 22: ...s for both devices Select Basic Serial Settings and enter Baud Rate Data Bits Parity Stop Bits the same parameter like has device connected to the serial port of the converter 5 2 2 1 5 INDUSTRIAL AUTOMATION MODBUS GATEWAY CONFIGURATION Choosing the Industrial Automation Modbus Gateway Fig 16 profile will be possible to configure ADA 13110MG for communication by the use of MODBUS RTU master slave ...

Page 23: ...ces table configuration of SLAVE type devices In section Destination Settings fig below set the options of requests from Master device to Slave device in fields Host name enter IP address of Slave device Protocol set protocol which will be send to Slave device in this case will be Modbus TCP Transport set TCP protocol Network port set port 502 Press Apply for saving configuration Then press again ...

Page 24: ...um delay or gap betweens bytes of a message default 20 ms Message timeout value in ms maximum delay or gap betweens bytes of a message default 2500ms this time must be less than the Timeout set on SLAVE and MASTER MODBUS RTU devices For saving the Advanced Protocol Settings press Apply Fig 29 Example configuration for communication with MODBUS MASTER devices configuration of timeout parameters for...

Page 25: ...G as Serial Slave and MODBUS RTU or MODBUS ASCII protocol for communication between connected devices Press Apply for saving configuration Fig 30 Example configuration for communication with MODBUS SLAVE devices choice of devices and protocols Set options in section Modbus RTU Settings eg As on picture below Press Apply for saving configuration Fig 31 Example configuration for communication with M...

Page 26: ...A HMI software For saving the Advanced Protocol Settings press Apply Fig 33 Example configuration for communication with MODBUS SLAVE devices configuration of timeout parameters for SLAVE type device 5 2 2 1 5 3 SERIAL PORT TRANSMISSION PARAMETERS For proper operation of ADA 13021MG with devices Modbus Master or Modbus Slave types connected to his serial port should be set the same transmission pa...

Page 27: ...net browser C User Permissions user permissions to configuration and management of the ADA 13021MG converter where are options None no permission Read permission to read Read Self permission to read own settings but not other users Read Write full permission to read and write the setting Read Write Self permission to read and write own setting but not other users Read All Write Self permission to ...

Page 28: ...or installation of virtual port driver and press Next 10 In window Describe the device select or not the Starting Com port and press Finish The driver will be installed The Virtual Serial Port Drivers can be installed without connection of ADA 13021MG to ETHERNET and it is as follows 1 Press Start button select Run 2 In the dialog window Run press Browse 3 Select My computer and CD Rom with ADANET...

Page 29: ...communication with virtual port driver 9 In the next window press OK to accept the changes Fig 34 Devices view on Windows XP Fig 35 Example configuration of multi port serial adapter 29 ADA 13021MG ...

Page 30: ...hen the converter will start with default settings Restoring Default Settings deletes existing configuration and the proper configuration should be loaded to the converter from the backup I changed the configuration and the converter isn t functioning 1 Enter in the Internet browser http converter ip address 2 Select the menu Factory Default Settings press Restore 9 VERSIONS ADA 13021MG Order exam...

Page 31: ...terface Electrical Parameters Power requirements 10 24 30 V DC Power Cable Recommended length up to 3m Power 3W Protection from reverse power polarization yes Galvanic Isolation 1kV or 3kV between power circuit and ETHERNET signal line 1kV or 3kV between power circuit and Current Loop signal line Optoisolation 3kV between signal lines Current Loop and ETHERNET Electromagnetic compatibility Resista...

Page 32: ...data transmission converters with interface RS232 RS485 RS422 USB Current Loop Fibre Optic Converters and Ethernet or Wi Fi Please contact us to tell how you like our products and how we can satisfy you present and future expectation CEL MAR sp j Zaklad Informatyki i Elektroniki Sciegiennego 219C str 25 116 Kielce POLAND Tel 48 41 362 12 46 Tel fax 48 41 361 07 70 Web http www cel mar pl en Office...