Selecting Command: 

To  select  a  command  use  the 

 

(increase) 

and 

 (decrease) keys are used to choose the 

function and select the data to enter; confirmation 
is via the 

“ENTER”

 key.  The commands are in a 

cyclical sequence:

 

 

 

 

 

This  can  occur  in  two  direction  by  pressing  the 

 and 

 keys. 

 

Transmission Channel: (CH) 

The  Transmission  channel  is  used  to  set  the 
frequency  of  the  metal  detector  this  comes  from 
the  factory  set  to  50.    This  should not be need  to 
change  unless  two  metal  detectors  are  in  relation 
to each other then both metal detectors need to be 
on two different channels. 

 

Factory Value: 50 
Isotec Recommended Value: anything from 50-99 
Possible Values: 0 

 99 

 

 49 is for 50Hz Power Supply 

 

50 

 99 is for 60Hz Power Supply 

 

Gate direction: (GD) 

The  gate  direction  selects  the  direction  of  transit 
through the antennae relative to the position of the 
archway. 

 

Factory Value: 1 
Possible Values: 1, 2 

GD=1:  If  you  look  at  the  gate  from  the  point 

of  entry  the  transmitter  (Tx)  antenna 
should be on the right. 

GD=2:  If  you  look  at  the  gate  from  the  point 

of  entry  the  transmitter  (Tx)  antenna 
should be on the left. 

 

(Only 02PN8 HI-PE & Bi Directional models) 

 

Alarm Duration: (AD) 

The  Alarm  duration  is  how  long  it  takes  the  metal 
detector to reset after an alarm. 

 

Factory Value: 1C 
Isotec Recommended Value: 1P 
Possible Values: 0P 

 5P; 0C 

 5C 

 
 
 
 
 

P = Proportional Alarm indication 

In  this  case  the  display  will  always  provide  an  indication 
proportional  to  the  metal  mass  in  transit,  using  the  red 
sector on the right when there is an alarm. 

C = Constant alarm indication 

In  this  case,  during  normal  operation  the  display  will 
indicate the selected sensitivity; when there is an alarm, 4 
asterisks light up in the red section on the right. 

 
0P 

 reset time = 0.3s  0C 

 reset time = 0.3s 

1P 

 reset time = 1s 

1C 

 reset time = 1s 

2P 

 reset time = 2s 

2C 

 reset time = 2s 

3P 

 reset time = 3s 

3C 

 reset time = 3s 

4P 

 reset time = 4s 

4C 

 reset time = 4s 

5P 

 reset time = 5s 

5C 

 reset time = 5s 

 

Alarm Volume: (AV) 

User  can  change  the  level  of  volume  during  a 
alarm. 

 

Factory Value: 3 
Possible Values: 0 

 9 

 
During  local  programming,  the  device  provides  an  audible  signal  using 
the selected tone. 

 

Alarm Tone: (AT) 

User can change the tone of the alarm. 

 

Factory Value: 2 
Possible Values: 0 

 9 

5 different continuous tones ranging from 

0

 (deep sound) 

to 

4

 (high sound) 

5 different pulsed tones ranging from 

5

 (deep sounds) to 

9

 

(high sound) 

 

During  local  programming,  the  device  provides  an  audible  signal  using 
the selected tone. 

 

International Security Standard: (IS) 

The  international  Security  Standard  is  a  security 
level  specified  by  international  regulations.    This 
command allows the adjustment of the detector to 
the  specification  of  selected  standard  without 
having to carry out the test procedure physically. 
 
Factory Value: 1 
Isotec Recommended Value:  

Isotec  recommended  that  the  IS  command  be  set  to 
customers  preference  for  what  they  would  like  to  detect 
and  adjusted  the  sensitivity***  of  the  metal  detector  to 
allow some devices. ie cell phones, and purses 

***To adjust see the Sensitivity command (SE) 

Possible Values: 1 

 10 

(See Table 1)

 

 

NOTE: if the 02PN8 Bidirectional model is being used, this 
command selects the International Security Standard to be 
applied for transits in the normal (inbound) direction

.  

 
 
 
 