11/26/2012 Metal Detecto Set-Up Ceia 02PN8 Series Page 2 of 3
Selecting Command:
To select a command use the
(increase)
and
(decrease) keys are used to choose the
function and select the data to enter; confirmation
is via the
“ENTER”
key. The commands are in a
cyclical sequence:
This can occur in two direction by pressing the
and
keys.
Transmission Channel: (CH)
The Transmission channel is used to set the
frequency of the metal detector this comes from
the factory set to 50. This should not be need to
change unless two metal detectors are in relation
to each other then both metal detectors need to be
on two different channels.
Factory Value: 50
Isotec Recommended Value: anything from 50-99
Possible Values: 0
–
99
0
–
49 is for 50Hz Power Supply
50
–
99 is for 60Hz Power Supply
Gate direction: (GD)
The gate direction selects the direction of transit
through the antennae relative to the position of the
archway.
Factory Value: 1
Possible Values: 1, 2
GD=1: If you look at the gate from the point
of entry the transmitter (Tx) antenna
should be on the right.
GD=2: If you look at the gate from the point
of entry the transmitter (Tx) antenna
should be on the left.
(Only 02PN8 HI-PE & Bi Directional models)
Alarm Duration: (AD)
The Alarm duration is how long it takes the metal
detector to reset after an alarm.
Factory Value: 1C
Isotec Recommended Value: 1P
Possible Values: 0P
–
5P; 0C
–
5C
P = Proportional Alarm indication
In this case the display will always provide an indication
proportional to the metal mass in transit, using the red
sector on the right when there is an alarm.
C = Constant alarm indication
In this case, during normal operation the display will
indicate the selected sensitivity; when there is an alarm, 4
asterisks light up in the red section on the right.
0P
–
reset time = 0.3s 0C
–
reset time = 0.3s
1P
–
reset time = 1s
1C
–
reset time = 1s
2P
–
reset time = 2s
2C
–
reset time = 2s
3P
–
reset time = 3s
3C
–
reset time = 3s
4P
–
reset time = 4s
4C
–
reset time = 4s
5P
–
reset time = 5s
5C
–
reset time = 5s
Alarm Volume: (AV)
User can change the level of volume during a
alarm.
Factory Value: 3
Possible Values: 0
–
9
During local programming, the device provides an audible signal using
the selected tone.
Alarm Tone: (AT)
User can change the tone of the alarm.
Factory Value: 2
Possible Values: 0
–
9
5 different continuous tones ranging from
0
(deep sound)
to
4
(high sound)
5 different pulsed tones ranging from
5
(deep sounds) to
9
(high sound)
During local programming, the device provides an audible signal using
the selected tone.
International Security Standard: (IS)
The international Security Standard is a security
level specified by international regulations. This
command allows the adjustment of the detector to
the specification of selected standard without
having to carry out the test procedure physically.
Factory Value: 1
Isotec Recommended Value:
Isotec recommended that the IS command be set to
customers preference for what they would like to detect
and adjusted the sensitivity*** of the metal detector to
allow some devices. ie cell phones, and purses
***To adjust see the Sensitivity command (SE)
Possible Values: 1
–
10
(See Table 1)
NOTE: if the 02PN8 Bidirectional model is being used, this
command selects the International Security Standard to be
applied for transits in the normal (inbound) direction
.