CEECO SSW-321-Xr1 Service Manual Download Page 5

ISSUE 4.0 

CEECO 

Communication Equipment & Engineering Company 

PROPRIETARY 

3.0 

PROGRAMMING 

 

NOTE: 

It is recommended that you ground yourself to prevent ESD 
damage to the PCB(s). 

 

*****WARNING*****

 

 
 

A.  

Never install telephone wiring during a lightning storm. 

 
 

B.  

Never install telephone jacks in wet locations unless the jack is   

 

 

specifically designed for wet locations. 

 

 

C.  

Never touch uninsulated telephone wires or terminals unless the

  

 

 

telephone line has been disconnected at the network interface. 

 

D.

 

Use caution when installing or modifying telephone lines. 

 

*If background noise elimination is desired, proceed with the following sections of 
programming.  Otherwise, the phone is ready to be installed and used. 

 

1)

 

Connect

 

the Ceeco XFD Series Telephone

 to the Telephone Line provided by your local 

            Telephone Company or to analog type PABX Station. 
 

2)

 

Using another Telephone (Different Telephone Line or cell phone) equipped with a Touch Tone 
Keypad, 

call the CEECO XFD Series Telephone

 

3)

 

After 4 rings

 of the CEECO Telephone, 

answer it

 by lifting the handset off hook and keep it that 

way.  Three tones should be heard indicating the phone is ready for remote input. 

 

4)

 

With the other phone, enter # 2 3 3 2 6 *

.  This is the factory default 5-digit pass code.  

Instructions for changing the pass code appear below.  

Two (2) beeps

 will be heard indicating a 

valid Pass Code entry.  Five (5) beeps will only be heard when an error occurs and programming 
was not accepted.  

Two (2)  beeps

 will always be given to indicate each successful programming 

entry below. 

 

 

Enter # 9 7 * to clear all memory.  It is not necessary to do this hereafter.  Individual 
programming options may be changed from time to time by entering only the necessary key 
presses and there is no requirement to “re-program” everything each time.   

 

 

 

 

 

If the environment is noisy and background noise elimination is desired, enter # 5 9 1 *. 

 

 

 

 

In order to change the Pass Code, enter # 3 1 x * (where x = any 5-Digit pass code).      

 

 

When programming is completed, simply hang up.        

 

 

            Release Firmware: xfd31_v1_1 

Summary of Contents for SSW-321-Xr1

Page 1: ...DEL SSW 321 Xr1 MINI WALL TELEPHONE EQUIPPED WITH XFD PRINTED CIRCUIT BOARD Serving the Telephone Industry Since 1930 Communication Equipment 519 W est South Park Street Engineering Company Okeechobee FL 34972 Voice 863 357 0798 Fax 863 357 0006 ...

Page 2: ...ECO for assistance MODEL NUMBER MODEL SSW 321 X STAINLESS STEEL MINI WALL TELEPHONE WITH XFD PRINTED CIRCUIT BOARD SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED For us to better serve you please have this information available when calling for technical support CEECO Communication Equipment Engineering Company 519 West South Park Street Okeechobee FL 34972 863 357 0798 Voice 863 357 0006 Fax ...

Page 3: ...Y 3 TABLE OF CONTENTS SECTION PAGE 1 0 INTRODUCTION 4 2 0 GENERAL DESCRIPTION 4 3 0 PROGRAMMING 5 4 0 OPERATION 6 5 0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 6 6 0 TESTING 6 7 0 SPECIFICATIONS 7 8 0 PARTS LIST 8 9 0 FCC NOTICE 9 10 0 REPAIR AND RETURN INFORMATION 10 ...

Page 4: ...XFD printed circuit board and is intended for ring down or direct connect operations In such applications the phone acts as the communication device only and is dependent upon the phone company or the PBX or similar device connecting any calls as desired This telephone is equipped with a receiver operated magnetic reed hookswitch which equates to fewer moving parts and a more sealed construction V...

Page 5: ...ipped with a Touch Tone Keypad call the CEECO XFD Series Telephone 3 After 4 rings of the CEECO Telephone answer it by lifting the handset off hook and keep it that way Three tones should be heard indicating the phone is ready for remote input 4 With the other phone enter 2 3 3 2 6 This is the factory default 5 digit pass code Instructions for changing the pass code appear below Two 2 beeps will b...

Page 6: ...y may be installed on any standard backboard 5 5 Run the inside station wire through the backplate assembly and terminate on to the RJ11C terminal block on the backplate 5 6 The use of a gas tube station protector is recommended The station ground should not exceed 50 ohms 5 7 Plug the modular line cord from the cover assembly into the RJ11C terminal block 5 8 Dress the line cable away from the se...

Page 7: ...NT 20mA min to 80mA max IMPEDANCE 600 ohms HEARING AID COMPATIBLE Meets EIA standards ENVIRONMENTAL Temperature 0oC to 50oC Humidity 20 90 non condensating ENCLOSURE Brushed 16 ga Stainless Steel MOUNTING Vertical surface mount WEIGHT 7 lb FCC REGISTRATION BW 88T7 13717 TE T UL LISTED NO 6OF5 RINGER EQUIVALENCY 0 1A TYPE JACK RJ11C ...

Page 8: ... Handset with Armored Cord 1 401 009 Ringer 1 301 592 Receiver Operated Magnetic Hookswitch 1 301 018 Modular Cord 1 321 015 Stainless Steel Backplate 1 321 016 1 4 20 x 3 4 Security Screw 1 301 005 Cable Ferrule 1 301 052 Grommet 1 301 6077 Volume Control Button ACCESSORIES 1 301 037 Security Tool OPTIONS 1 301 106 32 Handset with Steel Lanyard 1 301 106 18 Prison Short Cord Handset with Steel La...

Page 9: ...one Network through a registered jack provided by the telephone company in your area This jack is a modular outlet which you can order from your local telephone company 9 3 NOTIFICATION TO THE TELEPHONE COMPANY Before connecting this telephone the FCC requires that you notify your local telephone company business office The number is in the front of your phone book Tell them The line to which you ...

Page 10: ... to the defective unit This information must be inside the shipping container 10 2 DIRECT ALL INQUIRES TO CEECO Repair Department 519 West South Park Street Okeechobee Florida 34972 863 357 0798 10 3 NON WARRANTY REPAIR CEECO will repair equipment out of warranty for a set charge plus parts The customer must pay the shipping costs both directions 10 4 RETURN FOR CREDIT Material may be returned for...

Page 11: ...ind which have been caused by neglect abuse acts of God or improper operation of equipment CEECO will repair or replace any unit during this period if found to be defective for reasons other than abuse and improper use or improper installation It is the buyer s responsibility to return the defective unit to the factory CEECO will then repair or replace any defective parts and return them to the bu...

Reviews: