6.0  INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 

 

6.1

 

Using a 301-037 security tool (sold separately), loosen and remove the 
security screws. 

 

6.2

 

The security tool is for a standard 5/32" button head screw generally used 
on the framework of the phone booths. 

 

6.3

 

Separate the faceplate assembly from the weatherproof housing by pulling 
the faceplate forward.  

 

6.4

 

Run the inside station wire into the enclosure and terminate on the RJ11C 
terminal block inside, as depicted on the following page.  The CEECO 
provided terminal block (jack) 

must

 be used, as it contains required over-

voltage protection circuitry.  

 

6.5

 

The use of a gas tube station protector is recommended.  The station 
ground should not exceed 50 ohms.  

 

6.6

 

Plug the modular line cord from the faceplate assembly into the RJ11C 
terminal block. 

 

6.7

 

Dress the telephone line cord and AC cable away from the security screws 
and seat the faceplate into the weatherproof housing. 

 

6.8

  

Secure the cover assembly by tightening the security screws. 

 
 
 
                        

 

*****WARNING***** 

 
 

A.   Never install telephone wiring during a lightning storm. 

 

B.  

Never install telephone jacks in wet locations unless the jack 
is specifically designed for wet locations. 

 

C.   Never touch uninsulated telephone wires or terminals unless 

the telephone line has been disconnected at the network 
interface. 

 

D.

 

Use caution when installing or modifying telephone lines. 

Summary of Contents for SSP-570-D

Page 1: ...FOR MODEL SSP 570 D HANDS FREE ELEVATOR PHONE EQUIPPED WITH LOW POWER SPEAKER BOARD Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street Engineering Company Okeech...

Page 2: ...ce MODEL NUMBER MODEL SSP 570 D EQUIPPED WITH LOW POWER SPEAKER BOARD AND ATD 11 TONE DIALER SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED For us to better serve you please have this information...

Page 3: ...N PAGE 1 0 INTRODUCTION 4 2 0 GENERAL 4 3 0 PROGRAMMING 5 4 0 TESTING OPERATION 10 5 0 RECOMMENDED TOOLS AND TEST EQUIPMENT 11 6 0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS 11 7 0 SPECIFICATIONS 13...

Page 4: ...y vandal resistant Stainless Steel Panel Speakerphone Instead of a hookswitch and handset the SSP 570 D has a Press to start Press to stop button for the initiation and termination of phone calls This...

Page 5: ...copper pins This is the ON position which activates the Time Out Disconnect feature When the automatic call disconnect feature is not desired the jumper should be in the OFF position jumper bridges th...

Page 6: ...J3 position in small white print appears 11 bridging the middle and far left corner pins The J3 mini jumper should always be in this position regardless of the number you are programming Refer to diag...

Page 7: ...s then you should ignore this section If you happen to be in a long loop environment which takes more than one second to deliver dial tone on the line then you will need to locate the plastic mini jum...

Page 8: ...ISSUE 4 0 CEECO Communication Equipment Engineering Company PROPRIETARY 8 3 12 PROGRAMMING DIAGRAM FOR THE ADT11 BOARD...

Page 9: ...OARD CONFIDENTIAL This drawing and all information contained therein is confidential and is the exclusive property of CEECO and may not be copied reproduced or disclosed to anyone in any manner whatso...

Page 10: ...ll automatically disconnect if you programmed it as such Action Place a call to the telephone from another telephone Reaction The telephone rings Press the CALL button to answer the call The red LED i...

Page 11: ...ed as it contains required over voltage protection circuitry 6 5 The use of a gas tube station protector is recommended The station ground should not exceed 50 ohms 6 6 Plug the modular line cord from...

Page 12: ...GE PROTECTION DIAGRAM CONFIDENTIAL This drawing and all information therein is confidential and is the property of CEECO and may not be reproduced or disclosed to anyone in manner whatsoever or used f...

Page 13: ...ALING DTMF 70ms tone 50ms spacing OUTPUT 4 0 to 6 0dbm ENVIRONMENTAL Temperature o C to 50 C Humidity 20 90 non condensating PROGRAMMING Fifteen 15 hardware mini jumpers DIMENSIONS 6 825 W X 9 76 H X...

Page 14: ...026 OUTER COVER SECURITY SCREW 1 301 018 MODULAR LINE CORD 1 379 100 FACE PLATE 1 301 054 MODULAR CONNECTOR RJ11 1 570 200 SERVICE MANUAL 1 660 100 CEECO SPK BOARD 1 ADT 11 CEECO AUTO DIAL BOARD 1 602...

Page 15: ...Telephone Network through a registered jack provided by the Telephone Company in your area This jack is a modular outlet which you can order from your local telephone company 9 3 NOTIFICATION TO THE T...

Page 16: ...ctive unit This information must be inside the shipping container 10 2 DIRECT ALL INQUIRES TO CEECO Repair Department 863 357 0798 telephone 863 357 0006 facsimile info ceeco net www ceeco net 10 3 NO...

Page 17: ...or replacement of any part found to be defective by CEECO Under no circumstances shall CEECO be liable for loss damage cost of repair or consequential damages of any kind which have been caused by neg...

Reviews: