Issue 4.0
CEECO
Communication Equipment & Engineering Company
PROPRIETARY
8
6.0 INSTALLATION NOTES AND ASSEMBLY INSTRUCTIONS
6.1
Using a 301-037 security tool (sold separately), loosen and remove the
security screws.
6.2
The security tool is for a standard 5/32" button head screw generally used
on the framework of the phone booths.
6.3
Separate the faceplate assembly from the apparatus box by pulling the
faceplate forward.
6.4
The apparatus box is designed to be mounted flush on any flat vertical
surface. Mounting holes are provided on the back and all sides of the
apparatus box.(If applicable)
6.5
Run the inside station wire into the apparatus box and terminate on the
RJ11C terminal block inside.
6.6
The use of a gas tube, or carbon station protector is recommended. The
station ground should not exceed 50 ohms.
6.7
Plug the modular line cord from the faceplate assembly into the RJ11C
terminal block.
6.8
Dress the line cable away from the security screws and seat the faceplate
into the apparatus box.
6.9
Secure the faceplate assembly by tightening the security screws.
*****WARNING*****
A.
Never install telephone wiring during a lightning storm.
B. Never install telephone jacks in wet locations unless the jack is
specifically designed for wet locations.
C. Never touch uninsulated telephone wires or terminals unless
the telephone line has been disconnected at the network
interface.
D. Use caution when installing or modifying telephone lines.