12

 

11.0  REPAIR AND RETURN INFORMATION 

 
 
 
 

11.1

   WARRANTY REPAIR 

 

Any device returned requiring warranty service, repair or credit must be 
accompanied with a "Return Material Authorization" (RMA) FORM.  It 
must include return shipping instructions, original purchase order number 
and special marking instruction.  A description of the trouble observed 
must be attached to the defective unit.  This information must be inside the 
shipping container. 

 
 

11.2

   DIRECT ALL INQUIRES TO:

 

 
 

CEECO 

Repair Department 

863-357-0798- telephone 

863-357-0006- facsimile 

[email protected]

 

www.ceeco.net

 

 
 

11.3  

NON-WARRANTY REPAIR 

 

CEECO will repair equipment out of warranty for a set charge plus parts.  
The customer must pay the shipping costs both directions. 

 
 

11.4

   RETURN FOR CREDIT 

 

Material may be returned for credit only with prior approval. Material 
authorized for return is subject to a 20% restocking charge based on the 
manufacturer’s list price.  Return RMA must be requested no later than 30 
days after original shipment. 

 

 

Summary of Contents for SSP-561-D

Page 1: ...REE STAINLESS STEEL TELEPHONE WITH AUTOMATIC DIAL FEATURE EQUIPPED WITH SPK1 07 FIRMWARE OPTIONAL ADA FEATURE Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street Engineering Company Okeechobee FL 34972 Voice 863 357 0798 Fax 863 357 0006 ...

Page 2: ...ing CEECO for assistance MODEL NUMBER MODEL SSP 561 D W SPK1 07 FIRMWARE SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED For us to better serve you please have this information available when calling for technical support CEECO Communication Equipment Engineering Company 519 W South Park Street Okeechobee FL 34972 863 357 0798 telephone 863 357 0006 facsimile info ceeco net www ceeco net ...

Page 3: ...1 0 INTRODUCTION 4 2 0 GENERAL 4 3 0 PROGRAMMING 5 PROGRAMMING CONTINUED 6 PROGRAMMING CONTINUED 7 4 0 OPERATION 7 5 0 RECOMMENDED TOOLS AND TEST EQUIPMENT 7 7 0 TESTING 9 8 0 SPECIFICATIONS 9 9 0 PARTS LIST 10 10 0 FCC NOTICE 11 11 0 REPAIR AND RETURN INFORMATION 12 12 0 WARRANTY POLICY 13 13 0 DIAGRAM 14 ...

Page 4: ...006 facsimile info ceeco net www ceeco net 2 0 GENERAL 2 1 The CEECO hands free telephone is a sturdy vandal resistant stainless steel speakerphone with an optional ADA feature Instead of a hookswitch and handset the telephone has a press to start press to stop button for the initiation and termination of phone calls Manual volume control is also provided inside the telephone on the PC board 2 2 T...

Page 5: ...Enter 97 18 which will clear all user programmable memory NOTE Once the key has been entered you may hear a fast busy tone an operator recording or other Central Office signals Please disregard these sounds and continue programming as they will have no effect on the programming 3 5 Each programming location is accessed by dialing the sign and the corresponding two digit code The previous contents ...

Page 6: ...igit 8 0 Do not dial PBX access number 18 1 Dial PBX number stored in location 18 Digit 9 0 Always 0 for this model Digit 10 0 No wink detect 1 9 Length of the wink detect 1 50ms incremental to 450 ms 5 is recommended EXAMPLE Dial 00 0160000005 The phone will be set as follows Digit 1 Always 0 Digit 2 Incoming calls allowed Digit 3 6 minute conversation time out Digit 4 Always 0 Digit 5 Always 0 D...

Page 7: ...ial 18001234567 followed by a 1 second pause followed by the automatic dialing of the number programmed in section 3 7 3 9 When programming is finished press the CALL HANGUP button to hang up the phone Return the two mini jumpers to the off or outermost position as depicted on the last page of this manual Secure the telephone to its mounting The phone is now ready for use 4 0 OPERATION To make a c...

Page 8: ...tion wire into the apparatus box and terminate on the RJ11C terminal block inside 6 6 The use of a gas tube or carbon station protector is recommended The station ground should not exceed 50 ohms 6 7 Plug the modular line cord from the faceplate assembly into the RJ11C terminal block 6 8 Dress the line cable away from the security screws and seat the faceplate into the apparatus box 6 9 Secure the...

Page 9: ...seconds Action Finish the conversation Press the CALL HANGUP button to hang up the phone Reaction The LED goes out The call is terminated 8 0 SPECIFICATIONS Input Power C O Line Powered 48 52 Volt Loop Loop Current 23 mA min 80 mA max Impedance 600 Ohms Signaling DTMF 70 ms tone 50 ms spacing Output 4 0 to 6 0 dbm Environmental Temperature 0 C to 50 Humidity 20 to 90 Programming Via DTMF keypad Di...

Page 10: ...er cover security screw 1 301 018 Modular line cord 1 301 054 UL Modular Connector RJ11C 1 700 008 Keypad Cable 1 660 000 CEECO SPK PC board 1 705 110 Connectorized Keypad 1 6020 Momentary Panel Switch 1 14024 Speaker 1 14067 Microphone 1 391 002 Stainless Steel Panel 1 361 01 Mounting Box 1 12017 Ringer OPTIONS 1 301 037 Security Tool ...

Page 11: ...phone Network through a registered jack provided by the Telephone Company in your area This jack is a modular outlet which you can order from your local telephone company 10 3 NOTIFICATION TO THE TELEPHONE COMPANY Before connecting this telephone the FCC requires that you notify your local telephone company business office The number is in the front of your phone book Tell them The line to which y...

Page 12: ... to the defective unit This information must be inside the shipping container 11 2 DIRECT ALL INQUIRES TO CEECO Repair Department 863 357 0798 telephone 863 357 0006 facsimile info ceeco net www ceeco net 11 3 NON WARRANTY REPAIR CEECO will repair equipment out of warranty for a set charge plus parts The customer must pay the shipping costs both directions 11 4 RETURN FOR CREDIT Material may be re...

Page 13: ...eplace any unit during this period if found to be defective for reasons other than abuse and improper use or improper installation It is the buyer s responsibility to return the defective unit to the factory CEECO will then repair or replace any defective parts and return them to the buyer free of charge 12 2 PRINTED CIRCUIT BOARDS Printed circuit boards should not be repaired in the field If a un...

Page 14: ...When programming is completed move the mini jumpers to the OFF position NOTE Do not leave the mini jumpers in the ON position this will decrease battery life Move the mini jumpers to the ON position BEFORE going off hook Locate the mini jumpers on the corner of the PCB ON OFF ON OFF ON OFF ...