ISSUE 4.0
PROGRAMMING CONTINUED…
3.8
Programming is
completed
. Return the two
mini-jumpers
to the
"OFF"
position, as depicted on the last page of this manual. Remove the
programming keypad if an external keypad was used. Replace the
telephone assembly in its mounting/housing and replace and tighten the
security screws.
4.0 TESTING
4.1
Lift the handset, the telephone will wait for dial tone. When dial tone is
received the initial number will be dialed automatically if programmed as
such. Otherwise, the keypad is active for speed dialing. The handset
transmitter will be muted.
4.2
Press an (SBA) keypad button. The programmed number will be speed
dialed. The handset transmitter should be on now.
4.3
Keep the instrument off hook and allow the called party to hang up first.
Wait for the central office equipment to time out and return dial tone.
4.4
As soon as dial tone is received, three (3) tones will be heard. The phone
will momentarily open the line. The phone will then reset for another call.
The handset transmitter will be disabled.
4.5
Place a call into the telephone.
4.6
If incoming calls are not allowed, the handset transmitter will not turn on.
4.7
If incoming calls are allowed, the transmitter will turn on approximately
three (3) seconds after the incoming call is answered.
4.8
Attempt to "Hookswitch Dial" by tapping quickly on the hookswitch. The
telephone should hang up, seize the telephone line again and dial the
programmed number again, if so programmed.
5.0 RECOMMENDED TOOLS AND TEST EQUIPMENT
Volt
Meter
1/4" Nut Driver
Flat Blade Screw Driver
Security Tool 301-037
CEECO
Communication Equipment & Engineering Company
PROPRIETARY