ISSUE 4.0
CEECO
Communication Equipment & Engineering Company
PROPRIETARY
8
5.0 INSTALLATION
NOTES
AND ASSEMBLY INSTRUCTIONS
5.1
Using a 301-037 security tool (sold separately), loosen (do not remove)
the locking screw on the rear of the phone. The security tool is for a
standard 5/32" button head screw, generally used on the framework of the
phone booths.
5.2
Separate the cover assembly from the backplate assembly by pulling the
bottom forward and lifting up. The backplate assembly is designed rest on
any flat vertical surface.
5.3
Run the inside station wire into the enclosure and terminate on the RJ11C
terminal block inside. As depicted on the following page. The CEECO
provided terminal block (jack)
must
be used, as it contains required over-
voltage protection circuitry.
5.4
The use of a gas tube station protector is recommended. The station
ground should not exceed 50 ohms.
5.5
Plug the modular line cord from the cover assembly into the RJ11C
terminal block.
5.6
Dress the line cable away from the locking screw and install the cover
assembly by placing the two tabs into the two corresponding slots and
pushing forward until the housing slips into place for the security screw.
5.7
Secure the cover assembly by tightening the security screw on the rear of
the case.
*****WARNING*****
A.
Never install telephone wiring during a lightning storm.
B.
Never install telephone jacks in wet locations unless the jack
is specifically designed for wet locations.
C. Never touch uninsulated telephone wires or terminals
unless the telephone line has been disconnected at the
network interface.
D.
Use caution when installing or modifying telephone lines.