CEECO HOB-313-DD-48 Service Manual Download Page 14

ISSUE 4.0 

CEECO 

Communication Equipment & Engineering Company 

PROPRIETARY 

 

14 

13.0

 

DIAGRAM 

 

 

 
 

When programming is 
completed, move the mini 
jumpers to the 

OFF 

position. 

NOTE: 

Do not leave the mini jumpers in the ON position; 
this will decrease battery life. 

M

OVE THE MINI JUMPERS 

TO THE 

ON

 POSITION 

BEFORE

 GOING OFF

-

HOOK

Locate the mini jumpers 
on the corner of the PCB. 

O

N

O

FF

O

N

O

FF

O

N

O

FF

Summary of Contents for HOB-313-DD-48

Page 1: ...DD 48 TWO BUTTON AUTOMATIC DIALING PANEL TELEPHONE EQUIPPED WITH CAC4 04 42 FIRMWARE AND NVR1 0 MEMORY CONVERSION PCB Serving the Telephone Industry Since 1930 Communication Equipment 519 West South P...

Page 2: ...hen calling CEECO for assistance MODEL NUMBER MODEL HOB 313 DD 48 EQUIPPED WITH CAC4 04 42 FIRMWARE SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED For us to better serve you please have this infor...

Page 3: ...4 2 0 GENERAL 4 3 0 PROGRAMMING 5 PROGRAMMING CONTINUED 6 4 0 TESTING OPERATION 6 5 0 RECOMMENDED TOOLS AND TEST EQUIPMENT 6 6 0 INSTALLATION INSTRUCTIONS 7 7 0 SPECIFICATIONS 8 8 0 PARTS LIST 9 9 0...

Page 4: ...cessor based coinless panel phone designed to withstand abuse and fraudulent call attempts The transmitter is muted during periods of dial tone eliminating the use of hand held dialers Attempts to hoo...

Page 5: ...ll memory locations You must wait for two beeps indicating the memory has been cleared in order to proceed This may take up to two seconds 3 5 Enter 0 0 followed by 0 followed by 1 to allow incoming c...

Page 6: ...ial tone is received the transmitter is muted and the telephone waits for one of the three buttons to be pressed 4 2 Select the number to be dialed by pressing the desired button on the telephone Red...

Page 7: ...11C terminal block 6 5 The use of a gas tube station protector is recommended The station ground should not exceed 50 ohms 6 6 Plug the modular line cord from the telephone assembly into the RJ11C ter...

Page 8: ...s ENVIRONMENTAL Temperature 0 C to 50 C Humidity 20 90 non condensating PROGRAMMING Via DTMF keypad TELEPHONE PANEL 14 ga Stainless Steel DIMENSIONS 7 1 6 Wide x 11 1 4 High x 4 1 4 Deep Handset on ho...

Page 9: ...B Armored Cord Handset Blue 1 301 006 Ringer 1 301 009 Network 1 301 581 Tongue Bracket Assembly 1 301 589 Magnetic Hookswitch 1 301 018 Modular Line Cord 1 301 054 Modular Connector RJ11C 1 650 570...

Page 10: ...one Network through a registered jack provided by the Telephone Company in your area This jack is a modular outlet which you can order from your local telephone company 9 3 NOTIFICATION TO THE TELEPHO...

Page 11: ...ttached to the defective unit This information must be inside the shipping container 10 2 DIRECT ALL INQUIRES TO CEECO Repair Department 519 West South Park Street Okeechobee FL 34972 863 357 0798 10...

Page 12: ...d to be defective by CEECO Under no circumstances shall CEECO be liable for loss damage cost of repair or consequential damages of any kind which have been caused by neglect abuse act of God or improp...

Page 13: ...ISSUE 4 0 CEECO Communication Equipment Engineering Company PROPRIETARY 13 12 0 MODULAR JACK DIAGRAM...

Page 14: ...programming is completed move the mini jumpers to the OFF position NOTE Do not leave the mini jumpers in the ON position this will decrease battery life MOVE THE MINI JUMPERS TO THE ON POSITION BEFOR...