TESTING/OPERATION CONTINUED… 

 

4.6

 

Be sure to determine that the microphone is muting as programmed in 
section 3.5, and that the phone is in either DTMF (tone) dialing mode or 
pulse dialing mode, also as programmed in section 3.5.  DTMF sounds 
like definite tones or beeps, whereas pulse dialing sounds like rhythmic 
clicks.  If the phone does not seem to be functioning as programmed, hang 
up and repeat sections 3.2, 3.3, 3.5, and 3.10 only. If this does not solve 
the problem, please refer to section 8.2.

 

 

4.7 

Attempt to “hookswitch dial” by tapping quickly on the tongue of the 
hookswitch assembly.  The phone should momentarily open the line, until 
the attempt is over, and then return dial tone.  If not, please refer to section 
8.2.

 

 

4.8

 

Testing is now completed and the telephone is ready for operation.  Plug 
the telephone line cord into the desired location (RJ11C modular jack).  
The phone is now operational. 

 

 
 

 

 *****WARNING*****

  

 
 

A. 

 Never install telephone wiring during a lightning storm. 

 

B.

 

Never install telephone jacks in wet locations unless the     

 jack is specifically designed for wet locations. 

 

C.

 

Never touch uninsulated telephone wires or terminals       
unless the telephone line has been disconnected at the     
network interface. 

 

D.

 

Use caution when installing or modifying telephone lines. 

 

Summary of Contents for 403-F

Page 1: ...UAL FOR MODEL 403 F EXECUTIVE DESK TELEPHONE EQUIPPED WITH CAC6 00 FIRMWARE Serving the Telephone Industry Since 1930 Communication Equipment 519 W South Park Street Engineering Company Okeechobee FL...

Page 2: ...EECO for assistance MODEL NUMBER MODEL 403 F EQUIPPED WITH CAC6 00 FIRMWARE SERIAL NUMBER DATE MANUFACTURED LOCATION INSTALLED For us to better serve you please have this information available when ca...

Page 3: ...4 2 0 GENERAL 4 3 0 PROGRAMMING 4 PROGRAMMING CONTINUED 5 PROGRAMMING CONTINUED 6 PROGRAMMING CONTINUED 8 PROGRAMMING CONTINUED 9 4 0 TESTING OPERATION 10 TESTING OPERATION CONTINUED 11 5 0 SPECIFICA...

Page 4: ...F or pulse dialing automatically time and disconnect a phone call speed dial numbers and automatically dial one or two numbers typically access numbers when the handset is lifted As you can see this t...

Page 5: ...ions no incoming call allowed a wide dial tone detect window a muted microphone initially DTMF dialing and a 3 minute automatic timed call disconnect OPTIONS Digit 1 0 Implement Call restrictions see...

Page 6: ...ction 3 8 Combining the examples from this section and the one above entering 199 1818005551212 will program the phone to automatically dial 9 pause one second and automatically dial 1 800 555 1212 wh...

Page 7: ...ISSUE 4 0 CEECO Communication Equipment Engineering Company PROPRIETARY 7 corresponding speed dial numbers would automatically dial out This is true for all forty 40 speed dial locations...

Page 8: ...__ __ __ __ __ __ 57 __ __ __ __ __ __ __ __ __ __ __ 38 __ __ __ __ __ __ __ __ __ __ __ 58 __ __ __ __ __ __ __ __ __ __ __ 39 __ __ __ __ __ __ __ __ __ __ __ 59 __ __ __ __ __ __ __ __ __ __ __ 40...

Page 9: ...ook over the examples below When you are finished enter a location code 70 89 followed by a desired restriction pattern Do this for all desired allowed calling patterns All patterns may be programmed...

Page 10: ...If phone implemented call restrictions were programmed try some of them now The phone should only permit allowed calls to be dialed When a number is dialed that has not been programmed as allowed the...

Page 11: ...8 2 4 7 Attempt to hookswitch dial by tapping quickly on the tongue of the hookswitch assembly The phone should momentarily open the line until the attempt is over and then return dial tone If not pl...

Page 12: ...mum 80ma maximum IMPEDANCE 600 ohms SIGNALING DTMF OUTPUT 4 0 to 6 0dbm HEARING AID COMPATIBLE Meets EIA standards ENVIRONMENTAL Temperature 0oC to 50oC Humidity 20 90 non condensating TELEPHONE PANEL...

Page 13: ...1 022 Face Plate 401 015 Hookswitch Cradle Assembly 401 009 Ringer 301 009 Network 301 030 Instruction Card Kit 701 110 Chrome Keypad 650 521 MCRKII Printed Circuit Board 401 004 Handset 401 010 Modul...

Page 14: ...one Network through a registered jack provided by the Telephone Company in your area This jack is a modular outlet which you can order from your local telephone company 7 3 NOTIFICATION TO THE TELEPHO...

Page 15: ...o the defective unit This information must be inside the shipping container 8 2 DIRECT ALL INQUIRES TO CEECO Repair Department 863 357 0798 telephone 863 357 0006 facsimile info ceeco net www ceeco ne...

Page 16: ...d to be defective by CEECO Under no circumstances shall CEECO be liable for loss damage cost of repair or consequential damages of any kind which have been caused by neglect abuse acts of God or impro...

Page 17: ...When programming is completed move the mini jumpers to the OFF position NOTE Do not leave the mini jumpers in the ON position this will decrease battery life Move the mini jumpers to the ON position B...

Page 18: ...ISSUE 4 0 CEECO Communication Equipment Engineering Company PROPRIETARY 18...

Reviews: