6.4 Wiring GridScan/Mini
Follow the wiring diagram (Figure 3) to connect e.g GridScan/Mini with a single element detection signal to the door
controller. For the functional description for the GridScan/Mini safety light curtain please refer to the manual on
www.cedes.com.
Figure 3:
Wiring of the UPS Plus with the GridScan/Mini safety light curtain
NO
COM
NC
NO
U
SP
GND
COM
NC
Buzzer
Test
ON
OFF
LED
Power
Green
Power OK
No power
ON
OFF
Orange
Red
Input 1
Input 2
Outputs
-
Test
Test+
Test-
V V
Sensor connection
24 V
0 V
Input 1
Input 2
Test_out
Logic_sel
V V
V
V
V V
Output
relay 1
Power
N
CO
M
NC
NO
Output
relay 2
CO
M
NC
NO
L
V V
V
V V
V
V V
V
UPS Plus LED definition:
- Power LED (green) is ON, if supply voltage is connected correctly.
- Input LED (orange) is ON, if the protected area is obstructed.
- Input LED (red) is ON, if the protected area is obstructed.
Relay definition:
In the configuration shown, the relay is energized if there is
voltage applied and there is no obstruction. Contact between
COM and NO (safest connection).
Buzzer definition:
- Buzzer is OFF, if the protected area (light curtain) is not obstructed.
- The buzzer can be turned on/off by using a switch.
L
N
Protective
ground
Supply voltage:
20 ... 265 VAC
20 ... 375 VDC
GridScan/Mini
output relay 1
To the
door controller
Single element detection
output relay 2
GridScan/Mini
safety light curtain
Single element
detection
Test input
GridScan/Mini
Output
Logic selector
Input test signal
from the
door controller
brown
blue
black
green
white
gray