Cedes TOF/Start-EA Installation And Operation Manual Download Page 9

TOF/Start-EA

English

© CEDES | V 1.0

 

9

14. Maintenance

Although the TOF/Start-EA does not need regular 
maintenance, a periodical functional check is strongly 
recommended as follows:

 

Check the mounting position and detection area of the 
sensor.

 

Clean the optical window with a soft towel and a little 
soapy water.

15. Disposal

The TOF/Start-EA should only be replaced if a similar 
protection device is installed. Disposal should be done 
using the most up-to-date recycling technology according 
to local regulations and laws. There are no harmful 
materials used in the design and manufacture of the 
sensor. Traces of such dangerous materials may be found 
in the electronic components but not in the quantities that 
are harmful.

16. Technical data

Optical

Detection area 
- Length  

 

Min. 0 ... 400 mm 

   

 

Max. 0 ... 2,000 mm 

- Width  

 

Min. 0 ... 400 mm 

   

 

Max. 0 ... 2,000 mm

Mechanical

Dimensions (w × h × l) 

57 × 34 × 44.5 mm

Housing material    

Polycarbonate

Housing color  

 

Black

Enclosure rating 

 

IP65

Temperature range  

−20 °C ... +65 °C

Electrical

Supply voltage U

SP

   

24 VDC ±20%

Current consumption 

50 mA 

at 24 VDC 

 

(peak max. 0.5 A)

Output  

 

PNP/NPN (push-pull)

Max. response time 
  • Area without cross-traffic < 1 m  200 ms 
  • Area with cross-traffic > 1 m  400 ms
Min. switching time  

200 ms

Power-on time  

 

1 s

 
 
 
 

Connection cable and electrical connection
Sensor

Length 

 

0.25 m

Connection  

 

M8, 6-pin

Diameter  

 

Ø 4.2 mm

Material  

 

PVC, black

Plug color  

 

Blue

Connection cable

Length  

 

2 m 

 

 

(other lengths on request)

Connection  

 

M8, 6-pin

Diameter  

 

Ø 4.2 mm

Material  

 

PVC, black

Plug color  

 

Blue

Wires   AWG26

• 

brown  U

SP

• 

blue 

 

GND (0 V)

• 

black   Output

• 

white 

 

Not connected

• 

gray 

 

Selectable output logic

• 

green 

 

Not connected

General

Eye safety  

 

EN 62471:2008

EMC emission  

 

EN 61000-6-3:2007 

 

 

EN 12015:2014

EMC immunity  

 

EN 61000-6-2:2005 

 

 

EN 12016:2013

Vibration  

 

IEC 60068-2-6:2007

Shock  

 

IEC 60068-2-27:2008

RoHS  

 

2011/65/EU

Certificate  

 

CE

NOTICE

Damage to the optical window

 

Never use any solvents, cleaners or 
mechanically abrasive towels or highpressure 
water to clean the sensors.

Summary of Contents for TOF/Start-EA

Page 1: ...TOF Start EA Installation and Operation Manual 115 077 180226 V 1 0 English Pages 2 10 CEDES AG is certified according to ISO 9001 2015 RoHS ...

Page 2: ...cience Park CH 7302 Landquart Switzerland CEDES AG reserves the right to modify or change technical data without prior notice Contents 1 About this manual 2 1 1 Measurements 2 1 2 Related documents 2 1 3 CEDES headquarters 2 2 Safety information 3 2 1 Non intended use 3 3 Symbols safety messages 3 3 1 Safety messages categories 3 4 Introduction 4 4 1 Application 4 4 2 Features of the TOF Start EA ...

Page 3: ...or death 2 1 Non intended use The TOF Start EA must not be used for Protection of dangerous machines Equipment in explosive atmospheres Equipment in radioactive environments Use only specific and approved safety devices for such applications otherwise serious injury or death or damage to property may occur 3 Symbols safety messages 3 1 Safety messages categories Warning of serious health risks Cau...

Page 4: ...iguration 5 1 Type of threshold setting The distance at which the sensor triggers an output is the threshold The TOF Start EA requires a threshold setting for the x axis as well as the y axis using potentiometers A factory setting as well as a mixture of potentiometer and preset are also possible on request Note The sensor uses a 120 mm 4 72 in hysteresis The hysteresis is the difference between t...

Page 5: ...nfigured for HIGH on object or LOW on object operation Figure 5 according to the controller requirements The logic selection is performed during start up Figure 5 Output PNP NPN logic Figure 6 Connection diagram 8 Start up 1 Switch on mains and power up 2 Check if LED lights up 3 Check the distance setting and the reaction of the sensor including the status LED by placing an object into the detect...

Page 6: ... No object HIGH LOW HIGH LOW t2 t3 t1 t4 Off Dimmed Dimmed Bright X X X X HIGH on object Output Power supply LED status LOW on object Output Object detection Time Value ms Power on time t1 1 000 Max response time Area without cross traffic 1 m Area with cross traffic 1 m t2 200 400 Release time t3 200 Min switching time t4 200 ...

Page 7: ...ins at a 1 meter distance from the sensor Figure 10 Detection field free person moves towards the door entrance area LED status is dimmed Figure 11 Person is detected entering detection area moving towards the door entrance area LED status is bright Figure 12 Detection field free Person moves to cross the door entrance area LED status is dimmed Figure 13 Sensor recognizes the person is moving cros...

Page 8: ...detection field is free Figure 17 A static object is placed in the detection field i e a trash bag The object will be detected Figure 18 After 30 s the static object will be blanked out and the TOF Start EA continues its operation with the new geometry of the detection field 13 Trouble shooting If the problem persists please contact your local CEDES representative www cedes com LED dimmed LED dimm...

Page 9: ...aterial Polycarbonate Housing color Black Enclosure rating IP65 Temperature range 20 C 65 C Electrical Supply voltage USP 24 VDC 20 Current consumption 50 mA at 24 VDC peak max 0 5 A Output PNP NPN push pull Max response time Area without cross traffic 1 m 200 ms Area with cross traffic 1 m 400 ms Min switching time 200 ms Power on time 1 s Connection cable and electrical connection Sensor Length ...

Page 10: ... Dimensions 17 1 Sensor Measurements all dimensions in mm and inches 17 2 Mounting bracket Measurements all dimensions in mm and inches 57 2 24 34 1 34 52 2 05 44 5 1 75 41 5 1 63 29 1 14 68 35 2 69 31 7 1 25 25 33 35 1 31 40 1 57 51 4 2 02 ...

Page 11: ...TOF Start EA English CEDES V 1 0 11 ...

Page 12: ...CEDES AG Science Park CH 7302 Landquart Phone 41 81 307 2323 Fax 41 81 307 2325 info eu cedes com www cedes com TOF Start EA ...

Reviews: