TOF/Start-EA
English
© CEDES | V 1.0
9
14. Maintenance
Although the TOF/Start-EA does not need regular
maintenance, a periodical functional check is strongly
recommended as follows:
Check the mounting position and detection area of the
sensor.
Clean the optical window with a soft towel and a little
soapy water.
15. Disposal
The TOF/Start-EA should only be replaced if a similar
protection device is installed. Disposal should be done
using the most up-to-date recycling technology according
to local regulations and laws. There are no harmful
materials used in the design and manufacture of the
sensor. Traces of such dangerous materials may be found
in the electronic components but not in the quantities that
are harmful.
16. Technical data
Optical
Detection area
- Length
Min. 0 ... 400 mm
Max. 0 ... 2,000 mm
- Width
Min. 0 ... 400 mm
Max. 0 ... 2,000 mm
Mechanical
Dimensions (w × h × l)
57 × 34 × 44.5 mm
Housing material
Polycarbonate
Housing color
Black
Enclosure rating
IP65
Temperature range
−20 °C ... +65 °C
Electrical
Supply voltage U
SP
24 VDC ±20%
Current consumption
50 mA
at 24 VDC
(peak max. 0.5 A)
Output
PNP/NPN (push-pull)
Max. response time
• Area without cross-traffic < 1 m 200 ms
• Area with cross-traffic > 1 m 400 ms
Min. switching time
200 ms
Power-on time
1 s
Connection cable and electrical connection
Sensor
Length
0.25 m
Connection
M8, 6-pin
Diameter
Ø 4.2 mm
Material
PVC, black
Plug color
Blue
Connection cable
Length
2 m
(other lengths on request)
Connection
M8, 6-pin
Diameter
Ø 4.2 mm
Material
PVC, black
Plug color
Blue
Wires AWG26
•
brown U
SP
•
blue
GND (0 V)
•
black Output
•
white
Not connected
•
gray
Selectable output logic
•
green
Not connected
General
Eye safety
EN 62471:2008
EMC emission
EN 61000-6-3:2007
EN 12015:2014
EMC immunity
EN 61000-6-2:2005
EN 12016:2013
Vibration
IEC 60068-2-6:2007
Shock
IEC 60068-2-27:2008
RoHS
2011/65/EU
Certificate
CE
NOTICE
Damage to the optical window
Never use any solvents, cleaners or
mechanically abrasive towels or highpressure
water to clean the sensors.