2.  Safety information

The TOF/Start-EA was developed and manufactured using 
state-of-the-art systems and technologies. However, injury 
and damage to the sensor can still occur.

To ensure safe conditions:

 

Read all enclosed instructions and information.

 

Follow the instructions given in this manual carefully.

 

Observe all warnings included in the documentation 
and attached to the sensor.

 

Do not use the sensor if it is damaged in any way.

 

Keep the instruction manual on site.

The TOF/Start-EA should only be installed by authorized 
and fully trained personnel! The installer or system 
integrator is fully responsible for the safe integration 
of the sensor. It is the sole responsibility of the planner 
and/or installer and/or buyer to ensure that this product 
is used according to all applicable standards, laws and 
regulations in order to ensure safe operation of the whole 
application.

Any alterations to the device by the buyer, installer or user 
may result in unsafe operating conditions. CEDES is not 
responsible for any liability or warranty claim that results 
from such manipulation.

Failure to follow instructions given in this manual and/or 
other documents related to the TOF/Start-EA may cause 
customer complaints, serious call backs, damage, injury 
or death.

2.1  Non-intended use

The TOF/Start-EA 

must not

 be used for:

•  Protection of dangerous machines
•  Equipment in explosive atmospheres
•  Equipment in radioactive environments

Use only specific and approved safety devices for such 
applications, otherwise serious injury or death or damage 
to property may occur!

3.  Symbols, safety messages

3.1  Safety messages categories

Warning of serious health risks

Caution of possible health risk

Notice of damage risk

Symbol

Meaning

 

 

Single instruction or measures in no 
particular order

1.   
2.   
3.   

Sequenced instructions

•   

List, in no order of importance

à

Reference to a chapter, illustration or 
table within this document

Important

Important information for the correct use 
of the sensor

WARNING

Serious health risks

Highlights critical information for the safe 
use of the sensor. Disregarding these 
warnings can result in serious injury or 
death.

 

Follow the measures highlighted by the 
triangle-shaped arrows

 

Consult the safety information in 
Chapter 2 of this manual

IMPORTANT

READ BEFORE INSTALLATION!

CAUTION

Possible health risks

Highlights critical information for the safe 
use of the sensor. Disregarding these 
warnings can result in injury.

 

Follow the measures highlighted by the 
triangle-shaped arrows

 

Consult the safety information in 
Chapter 2 of this manual

NOTICE

Risk of damage

Disregarding these notices can lead to 
damage to the sensor, the door controller 
and/or other devices.

 

Follow the measures highlighted by the 
triangle-shaped arrows

Summary of Contents for TOF/Start-EA

Page 1: ...TOF Start EA Installation and Operation Manual 115 077 180226 V 1 0 English Pages 2 10 CEDES AG is certified according to ISO 9001 2015 RoHS ...

Page 2: ...cience Park CH 7302 Landquart Switzerland CEDES AG reserves the right to modify or change technical data without prior notice Contents 1 About this manual 2 1 1 Measurements 2 1 2 Related documents 2 1 3 CEDES headquarters 2 2 Safety information 3 2 1 Non intended use 3 3 Symbols safety messages 3 3 1 Safety messages categories 3 4 Introduction 4 4 1 Application 4 4 2 Features of the TOF Start EA ...

Page 3: ...or death 2 1 Non intended use The TOF Start EA must not be used for Protection of dangerous machines Equipment in explosive atmospheres Equipment in radioactive environments Use only specific and approved safety devices for such applications otherwise serious injury or death or damage to property may occur 3 Symbols safety messages 3 1 Safety messages categories Warning of serious health risks Cau...

Page 4: ...iguration 5 1 Type of threshold setting The distance at which the sensor triggers an output is the threshold The TOF Start EA requires a threshold setting for the x axis as well as the y axis using potentiometers A factory setting as well as a mixture of potentiometer and preset are also possible on request Note The sensor uses a 120 mm 4 72 in hysteresis The hysteresis is the difference between t...

Page 5: ...nfigured for HIGH on object or LOW on object operation Figure 5 according to the controller requirements The logic selection is performed during start up Figure 5 Output PNP NPN logic Figure 6 Connection diagram 8 Start up 1 Switch on mains and power up 2 Check if LED lights up 3 Check the distance setting and the reaction of the sensor including the status LED by placing an object into the detect...

Page 6: ... No object HIGH LOW HIGH LOW t2 t3 t1 t4 Off Dimmed Dimmed Bright X X X X HIGH on object Output Power supply LED status LOW on object Output Object detection Time Value ms Power on time t1 1 000 Max response time Area without cross traffic 1 m Area with cross traffic 1 m t2 200 400 Release time t3 200 Min switching time t4 200 ...

Page 7: ...ins at a 1 meter distance from the sensor Figure 10 Detection field free person moves towards the door entrance area LED status is dimmed Figure 11 Person is detected entering detection area moving towards the door entrance area LED status is bright Figure 12 Detection field free Person moves to cross the door entrance area LED status is dimmed Figure 13 Sensor recognizes the person is moving cros...

Page 8: ...detection field is free Figure 17 A static object is placed in the detection field i e a trash bag The object will be detected Figure 18 After 30 s the static object will be blanked out and the TOF Start EA continues its operation with the new geometry of the detection field 13 Trouble shooting If the problem persists please contact your local CEDES representative www cedes com LED dimmed LED dimm...

Page 9: ...aterial Polycarbonate Housing color Black Enclosure rating IP65 Temperature range 20 C 65 C Electrical Supply voltage USP 24 VDC 20 Current consumption 50 mA at 24 VDC peak max 0 5 A Output PNP NPN push pull Max response time Area without cross traffic 1 m 200 ms Area with cross traffic 1 m 400 ms Min switching time 200 ms Power on time 1 s Connection cable and electrical connection Sensor Length ...

Page 10: ... Dimensions 17 1 Sensor Measurements all dimensions in mm and inches 17 2 Mounting bracket Measurements all dimensions in mm and inches 57 2 24 34 1 34 52 2 05 44 5 1 75 41 5 1 63 29 1 14 68 35 2 69 31 7 1 25 25 33 35 1 31 40 1 57 51 4 2 02 ...

Page 11: ...TOF Start EA English CEDES V 1 0 11 ...

Page 12: ...CEDES AG Science Park CH 7302 Landquart Phone 41 81 307 2323 Fax 41 81 307 2325 info eu cedes com www cedes com TOF Start EA ...

Reviews: