background image

CEDES AG, Science Park | CH-7302 Landquart  

Phone: +41 81 307 2323 | Fax: +41 81 307 2325 | [email protected] | www.cedes.com

TOF/Spot

17.  Technical data

Optical

Operating range 

- Types P, C, T and I  

0.2 ... 6 m (0.7 ... 20 ft) 

- Type N 

 

0.2 ... 3 m (0.7 ... 10 ft)

Active light spot at 2 m distance  20 mm × 20 mm 

 

 

(0.79 in × 0.79 in 

 

 

at 6.5 ft)

Switching level 

- Types C and T  

 

0.15 m (5.9 in) 

 

 

from background

Measurement precision 

±5% at 2 m (at 6.5 ft) 

 

 

±10 cm (3.93 in) 

 

 

over the whole range

Max. ambient light   

100,000 Lux

 

Mechanical

Dimensions 

 

Ø 29.5 × 35.8 mm  

 

 

(1.16 × 1.41 in)

Housing material    

Polycarbonate

Housing color  

 

Black

Enclosure rating 

 

IP65

Operating temperature range  

−40 °C... +60 °C

Relative humidity   

0 ... 95% 

(non-condensing)

 

Electrical

Supply voltage U

SP

   

10 ... 30 VDC

Current consumption at 24 VDC  50 mA
Peak current consumption 

500 mA 

during power-up at 24 VDC
Output  

 

Solid-state relay

Max. switching voltage  

60 V

Max. switching current  

150 mA

Max power-up time  

1 s

 

Connection cable and electrical connection
Sensor

Length  

 

0.25 m

Connection  

 

Screwable, M8, 6-pin

Diameter  

 

Ø 4.2 mm

Material  

 

PVC, black

Plug color  

 

Blue

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connection cable

Length  

 

2 m (other lengths on request)

Connection 

 

Screwable, M8, 6-pin

Diameter  

 

Ø 4.2 mm

Material  

 

PVC, black

Plug color  

 

Blue

Wires 

 AWG26

• brown  

 

+U

SP

• black  

 

Output A

• green  

 

Output B

• blue  

 

GND (0 V)

• white  

 

Not used

• gray  

 

Logic selector

 

General

EMC emission  

 

EN 61000-6-3:2007, +A1:2011 

 

 

EN 12015:2014

EMC immunity 

 

EN 61000-6-2:2019,  

 

 

EN 12016:2013 

Vibration  

 

EN 60068-2-6:2008

Shock  

 

EN 60068-2-27:2009

Change of temperature   EN 60068-2-14:2009
RoHS  

 

2011/65/EU

Certificate  

 

CE

18.  Dimensions

Measurements

 all dimensions in mm (inches)

35.8 (1.41)

 Ø 34 (1.34)

 Ø 29.5 (1.16)

Summary of Contents for TOF/Spot

Page 1: ...English Pages 2 12 Original version 113 009 200512 V 4 0 Installation and Operation Manual TOF Spot CEDES AG is certified according to ISO 9001 2015 RoHS...

Page 2: ...odify or change technical data without prior notice Contents 1 About this manual 2 1 1 Measurements 2 1 2 Related documents 2 1 3 CEDES headquarters 2 2 Safety information 3 2 1 Non intended use 3 3 S...

Page 3: ...ious call backs damage injury or death 2 1 Non intended use The TOF Spot must not be used for Protection of dangerous machine Equipment in explosive atmospheres Equipment in radioactive environments U...

Page 4: ...l string replacement Loading dock stations Car barrier detection Figure 1 Car barrier detection 4 2 Features of the TOF Spot Exact distance setting independent of background Excellent detection capabi...

Page 5: ...eguarded area One output signals the detection of an object within the detection area Figure 5 Replaces pull string door opening Figure 6 Warehouse doors Figure 7 Car park barriers Figure 8 Bed detect...

Page 6: ...flat borders and where the edges are Important For proper functionality the remission range of the background or the object has to be between 2 90 Do not use high reflective retro reflective or mirror...

Page 7: ...t using the potentiometer located at the rear of the sensor Important When setting with the potentiometer use Figure 12 as the settings are not printed on the sensor Take a small screw driver and turn...

Page 8: ...stance This distance can only be changed by doing the setting process again 6 5 I type Initialized The I type has a specific detection range setting by factory according customer request Due to the po...

Page 9: ...with the controller 8 1 Mounting of snap in housing The mounting hole recommended for flush mounting is 30 to 31 mm The sheet thickness cannot be greater 3 mm 30 mm 0 5 1 18 in 0 019 0 3 3 mm 0 011 0...

Page 10: ...Open Figure 24 Timing diagram for relay output Time Value Power on time t1 1 000 ms Response time t2 60 ms Release time t3 60 ms Table 1 General timing table 12 LED signal LED status Description LED o...

Page 11: ...and a little soapy water NOTICE Damage to the optical window Never use any solvents cleaners or mechanically abrasive towels or highpressure water to clean the sensors 15 Disposal The TOF Spot should...

Page 12: ...DC Current consumption at 24 VDC 50 mA Peak current consumption 500 mA during power up at 24 VDC Output Solid state relay Max switching voltage 60 V Max switching current 150 mA Max power up time 1 s...

Reviews: