background image

English  

Pages 

2 – 12 

Original version

113 009 | 200512 | V 4.0

Installation and Operation Manual

TOF/Spot

CEDES AG is certified according to ISO 9001:2015

RoHS

Summary of Contents for TOF/Spot

Page 1: ...English Pages 2 12 Original version 113 009 200512 V 4 0 Installation and Operation Manual TOF Spot CEDES AG is certified according to ISO 9001 2015 RoHS...

Page 2: ...odify or change technical data without prior notice Contents 1 About this manual 2 1 1 Measurements 2 1 2 Related documents 2 1 3 CEDES headquarters 2 2 Safety information 3 2 1 Non intended use 3 3 S...

Page 3: ...ious call backs damage injury or death 2 1 Non intended use The TOF Spot must not be used for Protection of dangerous machine Equipment in explosive atmospheres Equipment in radioactive environments U...

Page 4: ...l string replacement Loading dock stations Car barrier detection Figure 1 Car barrier detection 4 2 Features of the TOF Spot Exact distance setting independent of background Excellent detection capabi...

Page 5: ...eguarded area One output signals the detection of an object within the detection area Figure 5 Replaces pull string door opening Figure 6 Warehouse doors Figure 7 Car park barriers Figure 8 Bed detect...

Page 6: ...flat borders and where the edges are Important For proper functionality the remission range of the background or the object has to be between 2 90 Do not use high reflective retro reflective or mirror...

Page 7: ...t using the potentiometer located at the rear of the sensor Important When setting with the potentiometer use Figure 12 as the settings are not printed on the sensor Take a small screw driver and turn...

Page 8: ...stance This distance can only be changed by doing the setting process again 6 5 I type Initialized The I type has a specific detection range setting by factory according customer request Due to the po...

Page 9: ...with the controller 8 1 Mounting of snap in housing The mounting hole recommended for flush mounting is 30 to 31 mm The sheet thickness cannot be greater 3 mm 30 mm 0 5 1 18 in 0 019 0 3 3 mm 0 011 0...

Page 10: ...Open Figure 24 Timing diagram for relay output Time Value Power on time t1 1 000 ms Response time t2 60 ms Release time t3 60 ms Table 1 General timing table 12 LED signal LED status Description LED o...

Page 11: ...and a little soapy water NOTICE Damage to the optical window Never use any solvents cleaners or mechanically abrasive towels or highpressure water to clean the sensors 15 Disposal The TOF Spot should...

Page 12: ...DC Current consumption at 24 VDC 50 mA Peak current consumption 500 mA during power up at 24 VDC Output Solid state relay Max switching voltage 60 V Max switching current 150 mA Max power up time 1 s...

Reviews: