Programmer's Guide
ObjectC 100
© CEDES Safety & Automation AG
http://csa.cedes.com/ 29
zone Z1
z1L = 1 z1H = 8
zone Z1
z1L = 1 z1L = 25
zone Z2
z2L = 9 z2H = 12
zone Z2
z2L = 3 z2H = 3
zone Z3
z3L = 13 z3H = 19
zone Z3
z3L = 4 z3H = 19
zone Z4
z4L = 20 z4H = 25
zone Z4
z4L = 14 z4H = 25
Figure 15: Two 10 mm pitch light curtains with defined zones.
4.9.
Overheight monitoring
It is sometimes very helpful to have an output signal if the transported goods exceed a certain height. This is
easily done with the Object 100 light curtain by defining the beam "oh". Beam "oh" defines a beam, which when it
or any higher beam is interrupted, causes the overheight output to be activated.
Figure 16: ObjectC 100 detects goods with an overheight.
"oh" = overheight beam number (inclusive)
4.10.
Overhang monitoring
Goods, which hang over the front or back edge of a pallet, may cause obstructions or damage during the
transport or storage process. The ObjectC
-
100 detects overhangs with one of the two following modes.