![Cedes IMS 100 Pro Series Installation And Operation Manual Download Page 9](http://html1.mh-extra.com/html/cedes/ims-100-pro-series/ims-100-pro-series_installation-and-operation-manual_2578745009.webp)
IMS 100 Pro
English
© CEDES | V 4.0
9
5.6 5 degree bracket
This bracket is used when the people/object detection
takes place too close to the elevator door i.e. the person or
object is detected too late.
The bracket also reduces the mounting height of the
sensor. This is useful when there is insufficient space in
the transom for the whole sensor. To mount the 5 degree
bracket the same mounting holes of the flush mounting kit
can be used.
5.6.1 Exchanging the bracket
1. Remove the optical cover by sliding it over the
mounting plate to the side (away from the cable outlet).
2. Remove the mounting plate by lessening the four
screws.
3. Replace the existing bracket with the 5 degree one.
4. Re-install the mounting plate using the four screws.
5. Place the optical cover back in place:
Position the optical cover to the right of the mounting
plate (1).
5 degree bracket
with fixing plate
Optical cover
IMS 100 Pro sensor
1
Figure 23:
Positioning of the optical cover
(ferrite core on cable not displayed)
Carefully press down on the left side of the cover (2)
and slide it from left to right (3). The cover is correctly
mounted when it is centered and cleanly locked in
position.
5 degree bracket
with fixing plate
Optical cover
IMS 100 Pro sensor
2
3
Figure 24:
Optical cover - press (2) and slide (3)
(ferrite core on cable not displayed)
5.7 If needed - removal of expanding rivets
Use a small slot screwdriver as shown to remove the
expanding rivets from the mounting bracket (Figure 25).
The rivets can be reused.
Figure 25:
Removing the rivets
6. Electrical installation
Make sure that the power supply voltage available for the
IMS 100 Pro is +24 VDC ±20%. The power supply has to
provide at least 250 mA for proper operation.
6.1 Cable and electrical connection of
IMS 100 Pro
Cable color
Connected to
Brown
U
SP
= 24 VDC ±20%
Blue
GND (0 VDC)
Black
Output (Door re-open signal)
White
U
SP
(Timeout selected)
(brown)
Output (black)
GND 0 VDC
(blue)
U
SP
(Timeout
selected - white)
Load
U
SP
µC
i
PNP
Figure 26:
Electrical connection IMS 100 Pro
6.2 Output logic
U
SP
0 V
Output
Status
No object
Object
detected
Door mode
Output
24 VDC
HIGH
0 VDC
LOW
24 VDC
HIGH
Red LED
OFF
ON
Blinking
Figure 27:
Output logic IMS 100 Pro