www.usaprocom.com
13
200028-01A
NG
LP
Right Side
of Heater
NG
LP
INSTALLATION
FLOOR CLEARANCES
Hearth
5"
Min.
Combustible
Material
14"
Min.
Combustible
Material
Noncombustible Material
Figure 8 - Minimum Fireplace Clearances
If Installed at Floor Level
Figure 9 - Minimum Fireplace Clearances
Above Combustible Flooring
A. If installing appliance on the floor level,
you must maintain the minimum distance
of 14" to combustibles (see Figure 8).
B. If combustible materials are less than 14"
to the fireplace, you must install appliance
at least 5" above the combustible flooring
(see Figure 9).
Fuel Selector Knob Hex Plug
Figure 10 - Settings for Natural Gas
Selection
Gas Connection Fitting
GAS SELECTION
This appliance is factory
preset for propane/LP gas.
No changes are required for
connecting to propane/LP.
Only
a qualified installer or service
technician can perform gas selec-
tion and connecting to gas supply.
CAUTION: Two gas line in-
stallations at the same time are
prohibited. The access plate
to the simple switching means
shall not be opened while the
heater is in operation.
CAUTION: To avoid gas
leakage at the inlet of regulator,
a qualified installer or service
technician must use supplied
hex plug with sealant.
WARNING: Do not attempt to
access or change the setting of
the fuel selection means.
Access to and adjustment of the fuel selection
means must only be performed by a qualified
service person when connecting this appliance to
a specified fuel supply at the time of installation.
Change of the selector setting to other than
the fuel type specified at the time of installa-
tion could damage this appliance and render
it inoperable.
The installer shall replace the access cover
before completing the installation and operat-
ing this appliance.
For changing from propane to
natural gas supply:
1. Remove bottom screw from cover plate.
Rotate to expose fuel selection device
(see Figure 10).
2. For natural gas, press in knob using a flat
screwdriver with a blade with thickness of a
quarter and turn knob clockwise
until
the knob locks into the NG position (see
Figure 10). Fuel selection device must be
locked in the NG position. Do not operate
heater between locked positions!
3. Replace cover over fuel selection device
and reinstall screws.
4. Remove hex plug (with wrench provided)
from natural gas inlet of regulator (see
Figure 10). Install hex plug into LP inlet
of regulator. Install gas line into NG inlet
of regulator. Use thread sealant to assure
there are no leaks.