7. TECHNICAL SPECIFICATIONS
Product reference: 05712
Product: Conga Triton 4000 UltraClean
AC220-240 V, 50/60Hz
Pressure washer
1500 W, 220-240 V~, 50/60 Hz
Rated pressure: 8 Mpa
Allowable pressure: 12 MPa
Rated flow: 5.5 l/min
Max. Flow: 6.0 l/min
Max. Inlet Pressure: 0.7 MPa
Vacuum cleaner
1200 W, 220-240 V~, 50/60 Hz
IP X5
Made in China | Designed in Spain
8. DISPOSAL OF OLD ELECTRICAL APPLIANCES
The European directive 2012/19/EU on Waste Electrical and Electronic
Equipment (WEEE), specifies that old household electrical appliances must
not be disposed of with the normal unsorted municipal waste. Old
appliances must be collected separately, in order to optimize the recovery
and recycling of the materials they contain and reduce the impact on
human health and the environment.
The crossed out “wheeled bin” symbol on the product reminds you of your obligation to
dispose of the appliance correctly. If the product has a built-in battery or uses batteries, they
should be removed from the appliance and disposed of appropriately.
Consumers must contact their local authorities or retailer for information concerning the
correct disposal of old appliances and/or their batteries.
6. TROUBLESHOOTING
Problem
Cause
Solution
The device does
not work
The device is not plugged in.
Defective socket.
Blown fuse.
Defective extension cord.
Plug in the device.
Try another socket.
Replace fuse. Switch off other
machines.
Try without the extension cord.
Fluctuating
pressure
Pump sucking air.
Valves dirty, worn out or
stuck.
Pump seals worn out.
Check that hoses and connections are
airtight.
Clean the device.
Contact the Technical Support Service
of Cecotec.
The device stops
working
Incorrect mains voltage.
Thermal sensor activated.
Nozzle partially blocked.
Make sure that the mains voltage
matches the voltage stated on the
rating label of the appliance and that
the wall outlet is grounded.
Leave the device for 5 minutes to cool
down.
Clean the nozzle.
Machine
pulsating
Air in inlet hose.
Inadequate supply of mains
water.
Nozzle partially blocked.
Water filter blocked.
Hose kinked.
Allow the device to run with open
trigger until regular working pressure
resumes.
Make sure that the mains voltage
matches the voltage stated on the
rating label of the appliance and that
the wall outlet is grounded.
Avoid using long, thin hoses.
Clean the nozzle or the filter.
Straighten out hose.
Machine starts,
but no water
comes out
Pump/hoses or accessory
frozen.
No water supply.
Water filter/nozzle blocked.
Wait for pump/hoses or accessory to
thaw.
Connect inlet water.
Clean the filter/nozzle.