ENGLISH
30
CLEANING CHARGING TERMINALS
•
Use a soft damp cloth to clean the charging terminals on the robot and on the
charging base.
•
Use a dry cloth to wipe the charging bones if the connection is poor.
CLEANING MAIN BRUSH KIT
•
Remove the main brush kit from the product’s main body, separate the cover from
the brush and clean them separately.
•
The brush can be washed in soap and water.
WARNING
: do not introduce the main brush back in its place unless it is completely dry.
BATTERY REMOVAL AND REPLACEMENT
1.
Remove the screws on the battery cover with a screw driver.
2.
Remove the battery cover.
3.
Remove the insulating tape on both sides of the battery and take it out.
4. Unplug the wire connector that links the battery and the robot.
5.
Introduce the new battery and make sure the side with printed words is facing upwards.
6.
Connect the cable from the battery to the robot.
7.
Introduce the battery into the compartment.
8. Screw back the battery’s cover.
Note
: only use the original battery provided by Cecotec, the use of a different one could cause
product damage.
Conga Serie 1290_Manual_GC.indd 30