background image

Cecomp

®

 ThermoPro

®

 Digital Temperature Transmitters 

T16L

cecomp.com

1220 American Way Libertyville, IL 60048 
Phone: 

800-942-0315

 

Fax: 800-949-7502

© 04-14

BSOLUTE

ROCESS NSTRUMENTS, Inc.

Division of

Range and Resolution

User selectable °F or °C 
  –58.0°F to 392.0°F 
  –50.0°C to 200.0°C 
0.1 degree resolution

Accuracy

Includes linearity, hysteresis, repeatability
±0.3°C at 0°C 
±1.1°C at 150°C
11-point linearization

Display

4 readings per second nominal display update rate 
4 digit LCD, 0.5" H 
5 character 0.25" H alphanumeric

 Low loop voltage indication 

ALARM1 under range indication on display 
ALARM2 over range indication on display 

Sensor

IEC-751 Class B 100 

 Platinum RTD, 0.00385 alpha curve 

1

/

2

" NPT male, 316L stainless steel 

All wetted parts are 316L stainless steel
Thermowell required for spring-loaded versions 
Spring-loaded probe fits standard thermowells
Fixed probe pressure rating: 5000 psi max. 
Fixed probes are welded to hex fitting

Analog Output

12,000 count 4-20 mA output  
Updated approximately 4 times per second
Temperature range configurable to correspond to 4-20 mA 
output 
Configurable for upscale or downscale burnout

Controls and Functions

3 button front keypad for setup, calibration, and configuration.
User-defined pass codes to prevent unauthorized changes.  
Pass code required for configuration and calibration.

 

O

100 

 Platinum RTD

 

O

316 Stainless Steel Probe

 

O

2 wire 4-20 mA Output with Programmable Range

 

O

–58.0°F to 392.0°F or –50.0°C to 200.0°C

 

O

NEMA 4X Housing

 

O

Spring-Loaded Versions for Thermowells

Specifications

How to Order

If you require a certain programming configuration to be pre-
set from the factory, please indicate it on your order.

Option—add to end of model number
-CC

  Conformal coating on circuit board for moisture  

 resistance

Output Test Function

When TEST button is held loop current and display are set to 
test level, independent of temperature input, to allow testing 
of system operation. Test level is user set.
Output test function can be pass code protected

Calibration

User settable pass code required to enter calibration 
mode 
Zero and span temperature calibration
Non-interactive zero, span, and linearity,  
±10% of range

Power

Any DC supply/loop resistance that maintains 8 to 32 VDC at 
gauge terminals 
Reverse polarity protected 
3 ft long, 2-conductor 22 AWG cable

Weight

Product: 

12 ounces (approximately) 

Shipping: 

1 pound (approximately) 

Housing Materials

ABS/polycarbonate NEMA 4X case, rear gasket, polycarbonate 
label, aluminum sensor block

Storage Temperature

–40 to 203°F (–40 to 95°C)

Operating Range

–4 to 185°F (–20 to 85°C) at housing

Model

Length

 

T16L2

 

2.5" L fixed length

 

T16L4

 

4" L fixed length

 

T16L6

 

6" L fixed length

 

T16L9

 

9" L fixed length

 

T16L12

 

12" L fixed length

 

T16L2S

 

2.5" L spring-loaded

 

T16L4S

 

4" L spring-loaded

 

T16L6S

 

6" L spring-loaded

 

T16L9S

 

9" L spring-loaded

 

T16L12S

 

12" L spring-loaded

See thermowell manufacturer’s specifications. 

Probe length 

is measured from top of full threads to tip of probe

.

Wiring

Dimensions

Cecomp maintains a constant effort to upgrade and improve its products. 
Specifications are subject to change without notice. Consult factory for your 
specific requirements.

Spring-loaded RTD probes MUST be used with a thermowell. 
Length = thermowell “S”, “L”, “A” or “stem length” dimen-
sion. See your thermowell manufacturer’s specifications. 
NOTE: probe length is NOT the same as thermowell insertion 
depth. 
Consult factory for custom probe lengths.

Thermowell 

Stem 

Length 

1/2” NPT 

316 stainless

Connection to the T16L is made with the 2-wire cable at the 
gauge rear. Reversing the connections will not harm the gauge 
but it will not operate with incorrect polarity. See the wiring 
examples below for connecting to a 4-20 mA current loop.

If the 4-20 mA analog output is not required, the transmitter 
will function as a low voltage powered temperature indicator 
when connected to any 8 to 32 VDC power supply. Connect 
the loop (+) supply to the RED lead and the loop (–) supply to 
the BLACK lead. 

RED +

 

BLACK –

Power (+) 

Power (–)

mA meter (–) 

mA meter (+)

Power (–) 

Power (+)

mA meter (+) 

mA meter (–)

BLACK – 

RED +

- or -

Power (–) 

Power (+)

BLACK – 

RED +

3 ft long, 2-conductor 

22 AWG cable

.75"

2.0"

Hex nipple  

1/2" NPT x 1/2" NPT 

 316 stainless

Spring-loaded models

approx. 0.25" longer 

to compress element 

in thermowell.

0.50" max.  

compression

1.25"

3.5"

0.75"

0.25" dia.

Stem 

Length  

L

Continuous weld 

on non-spring 

loaded models

1.37"

3.0"

X X X X X

88888

ALARM 2

ALARM 1

t

s

Measured from 

top of full threads 

to tip of probe. 

Length L = 

thermowell “A” 

or “element 

length”

Turn at 

hex 

fitting 

only!

Low power 

indication

TEST

Quick Link 

cecomp.com/ThermoPro

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

  H H H H H

 H H H H H H

Made in USA

Reviews: