protection device observe the grinding quality and noise level, and if there are any irregularities shut down the
appliance and call a certified technician for a complete analysis of the appliance.

B) Grinding Chamber Safety Screws

The grinding chamber can be a hazardous area if the proper precautions aren’t observed. The hopper safety
screw (fig 4.1) and the grinding dial safety screw (fig 5.1) should never be removed during normal operation of
the appliance unless the appliance is disconnected from the power source.

C) Coffee Outlet Guard

The coffee outlet guard (fig 6.3) must always be fixed to the doser. Never remove the securing screws.

7) Safety Instructions

• NEVER OPERATE THE GRINDER IF THE BEAN HOPPER IS NOT FULLY SECURED TO THE TOP BLADE

HOLDER. BEFORE REMOVING THE HOPPER FOR ANY REASON MAKE SURE TO DISCONNECT THE
POWER SUPPLY.

• AVOID CLEARING FOREIGN OBJECTS FROM THE GRINDING CHAMBER OR HOPPER WHEN THE

APPLIANCES PLUGGED INTO A POWER SOCKET.

• Never attempt to insert your fingers or any foreign objects into the grinding chamber or blades.
• Be aware that grinding blades continue rotating for a short while after the grinding operation has ended.
• BEFORE ANY MAINTENANCE, EVEN FOR CLEANING, ALWAYS DISCONNECT THE POWER SUPPLY.
• In the event that the appliance has a malfunction or the blades need to be replaced, do not attempt to service

the appliance by yourself.

• Do not change or tamper with the appliance.
• Do not use the appliance barefoot or if your hands or feet are damp.
• Do not use the cable wire to pull and disconnect the power plug.
• Always keep the appliance dry (internally and externally).
• Never put ground coffee into the hopper.
• Never attempt grinding anything else other than coffee beans.

8) Maintenance and Service

Warning: All appliances’ technical handling operations, such as installation, maintenance, or
service should be performed by certified personnel or by your local dealer.

Following this rule will ensure long-lasting and reliable performance of your appliance. Check the state of the
grinding blades periodically (approximately every 110 lbs. ground coffee). Good condition blades will result in
a high quality grind and prevent the appliance’s over-heating. Replace grinding blades every 900 lbs. of
ground coffee (with normal hardness blades).
Be aware of the appliance’s noise level. In case the noise level is higher than normal or irregular noises are
coming from within the appliance, get certified personnel to perform an overall check of the appliance.

9) Cleaning

BEFORE ANY CLEANING ROUTINE DISCONNECT THE APPLIANCE POWER SUPPLY. NEVER USE
RUNNING WATER TO CLEAN THE MAIN BODY AND DOSER. USE ONLY PERFECTLY CLEAN CLOTHS OR
BRUSHES TO CLEAN THE APPLIANCE. DO NOT USE ABRASIVE CLEANING PRODUCTS AS THEY MAY
WEAR OUT THE APPLIANCE COATING.

• Cleaning the bean hopper

Take off the bean hopper and rinse it thoroughly with water and soap. Before reinstalling the hopper to the
upper blade holder, make sure it is dried thoroughly.

Figure 6.3

Outlet Guard

!

Summary of Contents for VENEZIA II HC-600

Page 1: ...Espresso Grinder Instruction Manual Cecilware Corporation NR32A 1 10 Since 1911 VeneziaII Model HC 600 ...

Page 2: ...al Specifications Pg 3 3 General Description Pg 3 4 Unpacking and installation Pg 4 5 Operation Pg 4 6 Safety devices Pg 5 7 Safety instructions Pg 6 8 Maintenance and service Pg 6 9 Cleaning Pg 6 10 Part Diagram Pg 8 11 Part List Pg 9 ...

Page 3: ...eference The manufacturer reserves the right to modify the appliance and the manual accordingly 2 Technical Specifications HC 600 Dimensions Height Width 8 5 Length 13 Weight 30 lbs Stainless Steel Burrs Diameter 64mm Hopper capacity 3 lbs of beans Timer 5 min Electrical Specifications USA 110V 60Hz Power 350w 1600RPM Duty Cycle 50 Materials Metallic Aluminum alloy cast Stainless steel screws and m...

Page 4: ...quency rating according to the back side label is the same as the supply mains o The wall socket is fitted with an efficient ground contact DO NOT plug the appliance into the supply mains if the ground system was not positively checked to be in compliance with current safety rules IT IS COMPULSORY TO GROUND THE APPLIANCE The manufacturer cannot be held responsible in the event that this regulation i...

Page 5: ...ied all the way into the fork shaped support and dose one or two portions In order to achieve repeatable and consistent portioned amounts o Make sure that the feeding star shaped mechanism is always over filled with coffee o Always retract the dosing lever all the way to the end of its stroke Pressing Place the porta filter holder against the underside of the pressing device and push it upwards 6 Sa...

Page 6: ...or tamper with the appliance Do not use the appliance barefoot or if your hands or feet are damp Do not use the cable wire to pull and disconnect the power plug Always keep the appliance dry internally and externally Never put ground coffee into the hopper Never attempt grinding anything else other than coffee beans 8 Maintenance and Service Warning All appliances technical handling operations suc...

Page 7: ...ly of a new set of blades is a delicate task Only skilled technical personnel should be allowed to perform blade removal and assembly After all cleaning and replacing tasks are through make sure to assemble all of the parts and safety screws the same way as they were disconnected If anything does not fit back together or there are left over parts do not attempt to operate the appliance call for the...

Page 8: ...8 10 Part Diagram ...

Page 9: ...er Dia Part Description 3 0 6 9 Dispenser Lid 38 0 680 Switch Set 39 40 41 4 0 681 Dispenser Window 43 0 68 Dispenser Housing 0 683 Sponge Washer 44 0 684 Adjuster Stopper M5x10 45 0 685 Dispenser Adjusting Knob 46 0 686 Wiper 4 0 68 Dispenser Screw M5x8 0 688 Dispenser Screw M5x1 48 0 689 Tamper 5 mm 49 0 690 Dispenser Top Revolver 50 0 691 Dispenser Revolver Cover 51 0 69 Dispenser Revolver 5 0 ...

Page 10: ...Cecilware Corporation 43 05 20th Avenue LIC NY 11105 Tel 800 935 2211 718 932 1414 Fax 718 932 7860 www cecilware com Email customer service cecilware com Since 1911 ...

Reviews: