LA VENEZIA-17 ESPRESSO MACHINE USER MANUAL
17
Regenerate the filter.
To disable the alarm and reset the counter:
Turn off the machine. Simultaneously press and hold down the
“
2 espresso
”
and
“
2
coffee”
buttons. Turn on the machine.
Reset the configuration to default
Reset the control box to default values allows erasing all the custom parameters of the
control box and replacing them by the loaded on the EEPROM memory. This procedure can
restart a machine that is not working properly due to software issues.
If a reset to default is done, most of the parameters of the machine must be programmed
again following the indications on Chapter III.
To set all values to default you must turn off the machine with the main switch (1), press the “1
espresso”, “2 espresso” and “continuous” buttons of the group 1 keyboard.