Spare Parts List 

 

No. Description 

QTY 

Part 

NO 

1 WATER 

PAN 

08056 

HEATING ELEMENT - 120V, 1500W 

08057 

ELEMENT FIXING PLATE 

NA 

4 INSULATION 

NA 

5 INSULATION 

COVER 

NA 

6 PAN 

HOLDERS 

08058 

7 MAIN 

BODY 

NA 

8 BASE 

PLATE 

NA 

9 FEET 

08059 

10 THERMOSTAT 

DIAL 

08060 

11 THERMOSTAT 

 

08027 

12 PILOT 

LIGHT 

08032 

13 ON/OFF 

SWITCH 

08054 

14 HI-LIMIT 

08079 

15 

CORD & PLUG   

08055 

16 DRIP 

TAP 

08089 

17 

FLEXIBLE HOSE CONNECTION 

08090 

18 STUFFING 

PLUG 

08091 

*NA = not available except by special order. 

 

Specifications 

 

MODEL VOLTAGE 

POWER 

DIMENSIONS (INCHS) 

W

×

D

×

H

 

FW-25 

120V 

50/60 HZ 

1500W 14 

3/8

×

23 1/2

×

10 1/2

 

FW-25WT 

120V 

50/60 HZ 

1500W 14 

3/8

×

25 3/4

×

10 1/2

 

Summary of Contents for FW-25

Page 1: ...TRIC COUNTER TOP WARMER OPERATION MANUAL FW 25 FW 25WT FW 25 Shown CECILWARE CORPORATION 43 05 20 th AVENUE LONG ISLAND CITY NEW YORK 11105 1295 718 932 1414 FAX 718 932 7860 www cecilware com NN56A 5...

Page 2: ...ackaging page 2 Installation page 2 Operation page 2 Cleaning Care and Maintenance page 3 Safety page 3 Trouble Shooting page 3 4 Compliance page 4 Electrical Diagram page 5 Explosion View page 6 Spar...

Page 3: ...mmediately Installation Remove the Counter Top Warmer from the packaging Be certain all protective plastics and residues are thoroughly cleaned from its surface Place the Warmer on a firm level surfac...

Page 4: ...g To avoid over heating or damage to the element this unit has been installed with a Hi Limit If the Hi Limit is tripped please call a Recommended Qualified Service Technician to check over the warmer...

Page 5: ...ater in the pan 1 Fill the pan to the indicated level between Min and Max 2 Thermostat setting 2 Ensure that the thermostat is set correctly and the dial is not spinning Slow heat up 3 Faulty element...

Page 6: ...ight hi limit thermostat 120V on off switch The above circuit diagram has been provided to assist qualified technicians A Recommended Qualified Service Technician should carry out repairs if needed Do...

Page 7: ...Explosion View FW 25 6 13 10 11 12 8 9 7 15 2 14 4 5 3 1 FW 25WT 17 18 15 1 2 4 3 14 6 8 7 13 9 11 10 12 5 6...

Page 8: ...9 FEET 4 08059 10 THERMOSTAT DIAL 1 08060 11 THERMOSTAT 1 08027 12 PILOT LIGHT 1 08032 13 ON OFF SWITCH 1 08054 14 HI LIMIT 1 08079 15 CORD PLUG 1 08055 16 DRIP TAP 1 08089 17 FLEXIBLE HOSE CONNECTIO...

Page 9: ...CECILWARE CORPORATION 43 05 20 th AVENUE LONG ISLAND CITY NEW YORK 11105 1295 718 932 1414 FAX 718 932 7860 www cecilware com 8...

Reviews: