background image

 

4

 

Cleaning, Care and Maintenance 

 
Switch off the power and disconnect from the power source. 
 
The fryer should be cleaned after each day’s operation, however it may require to be cleaned more 
often, depending on the volume of production. 
 
The fryer must be left to cool before cleaning. Empty oil from the pan. If the oil is to be reused, it is 
recommended that it be filtered with the Cecilware Frysaver® Filtration System to ensure longer yield 
and a better quality in the cooked product. 

Note: the 15 lb. fryer is fitted with a drain valve. 

 
Once the oil has been emptied from the fryer, the control box can be tilted back to remove the pan from 
the body. The pan can be washed using warm soapy water. 
 
The main body can also be washed in warm soapy water, but be sure to unclip the control box and 
element first. The control box 

cannot 

be immersed in water; however, the control box can be wiped 

down with a damp cloth. Warm soapy water is recommended for cleaning. Prolonged use of cleaning 
agents can damage stainless steel.   

 

Safety 

 
*The Cecilware fryer does not contain 

any

 user-friendly parts. A Cecilware Recommended Qualified 

Service Technician should carry out repairs if necessary. Do not remove any components or service 
panels on this product. 
 
*Switch off power to and disconnect from the main power source while cleaning. 
 
Ensure oil levels are maintained above the minimum indicated level in the fryer. Failing to maintain the 
required level may result in fire. 
 
Ensure oil is changed regularly. Used oil breaks down after use and can result in fire, as its flash point is 
reduced, and it is more prone to surge boiling. 
 
Note: products containing humidity/moisture will cause surge boiling when placed in hot oil. 
 
The basin should remain uncovered during frying. 
 
Hot oil causes serious damage to skin. Avoid skin contact with hot oil. 
 
Do not immerse unit in water or use water jets to clean. 
 
If the power cord is damaged, it must be replaced by a 

Cecilware Service

 

Agent or Recommended 

Qualified Service Technician

 in order to avoid a hazard. 

 

Important Note: 
 
Caution: 

All double pot Fryers has two power supply cords. Each Fryer pot is independently controlled. Connect 

each plug to a receptacle that is connected to an individual branch circuit. Unplug both cords before 

installing, cleaning, moving, or servicing this appliance. 
 
 
 

 

Summary of Contents for EL-15

Page 1: ...Single Double models OPERATION MANUAL EL 6 EL 15 EL 25 EL 2x6 EL 2x15 EL 2x25 EL 2x6 Shown CECILWARE CORPORATION 43 05 20 th AVENUE LONG ISLAND CITY NEW YORK 11105 1295 718 932 1414 FAX 718 932 7860 w...

Page 2: ...ckaging page 2 Installation page 2 3 Operation page 3 Cleaning Care and Maintenance page 4 Safety page 4 Trouble Shooting page 5 Compliance page 6 Electrical Diagram page 6 Explosion View page 7 8 Spa...

Page 3: ...d model Basket s Manual Should you find any damage as a result of freight please contact your Cecilware dealer immediately Installation Remove the Cecilware fryer from the packaging be certain all pro...

Page 4: ...he fryer has been installed correctly please consult the specification chart page 10 for the required volume of cooking oil Turn the thermostat dial towards the ON position the amber light will activa...

Page 5: ...ain any user friendly parts A Cecilware Recommended Qualified Service Technician should carry out repairs if necessary Do not remove any components or service panels on this product Switch off power t...

Page 6: ...ndicator light is off 6 Thermal cut out has activated 6 Remove reset button cover A press button B to reset See Diagram for Thermal Cut Out Reset below If problem persists call service agent or qualif...

Page 7: ...ch compliance Cecilware products carry the following marks symbols Electrical Diagram pilot light heating element thermostat hi limit micro switch 120 240V on off switch The above circuit diagram has...

Page 8: ...Explosion View EL 6 17 15 16 11 13 14 9 18 10 2 20 19 1 6 3 7 12 8 5 4 EL 15 EL 25 7 12 16 15 14 6 3 2 18 9 17 13 10 11 20 19 5 8 4 1 7...

Page 9: ...EL 2 x6 15 16 20 2 18 19 17 14 13 12 8 11 10 9 3 4 5 6 1 7 EL 2 x15 EL 2 x25 8 16 15 2 17 11 10 12 14 13 19 20 7 8 18 9 3 4 5 6 1...

Page 10: ...ot Light 240 V NA NA NA NA 1 08067 2 08067 9 Stuffing Box 2 NA 4 NA 2 NA 4 NA 10 Element Cover 1 NA 2 NA 1 NA 2 NA Heating Element 120 V 1 08051 2 08051 1 08034 2 08034 11 Heating Element 240 V NA NA...

Page 11: ...MENSIONS WxDxH EL 6 6 lbs 7 x17 x12 EL 15 15 lbs 120V 1 8KW 15A 11 x17 x15 EL 25 15 lbs SINGLE TANK 240V 3 2KW 15A 11 x17 x15 EL 2x6 2x 6 lbs 14 x17 x12 EL 2x15 2x 15 lbs 120V 2x 1 8KW 2x 15A 21 x17 x...

Page 12: ...CECILWARE CORPORATION 43 05 20 th AVENUE LONG ISLAND CITY NEW YORK 11105 1295 718 932 1414 FAX 718 932 7860 www cecilware com 11...

Reviews: